Appendix
11-29
BA9300SU EN 2.1
Code
Important
Possible settings
LCD
Code
Important
Choice
Lenze
LCD
C0356
1
2
3
4
&$1 %227 83
287 EWEMF
287 EWEMF
&$1 '(/$<
3000
0
0
20
0
{1 ms}
65000
CAN bus time settings
1: CAN Boot-Up
2: CAN-OUT2 cycle
3: CAN-OUT3 cycle
4: CAN OUT 2/3 delay time
[C0357]
1
2
3
&(NO1JS SJNF
&(NO1JS SJNF
&(NO1JS SJNF
3000
3000
3000
0
{1 ms}
65000
CAN bus monitoring time for I
ratedx
C0358
5FRFS 1O'F
0
0
no function
1
CAN reset
Install CAN bus reset node
C0359
&$1 RSDSF
g
0
Operational
1
Pre-Operat
2
Warning
3
Bus off
CAN bus status:
C0360
1
2
3
4
5
6
7
8
9
10
11
12
0FRRDHF 287
0FRRDHF ,1
0FRRDHF 287
0FRRDHF 287
0FRRDHF 287
0FRRDHF 3287
0FRRDHF 3287
0FRRDHF ,1
0FRRDHF ,1
0FRRDHF ,1
0FRRDHF 3,1
0FRRDHF 3,1
g
0
{1}
65535
Telegram counter (number of telegrams, with
values > 65535 counting starts again at 0)
1: all sent
2: all received
3: sent to CAN-OUT1
4: sent to CAN-OUT2
5: sent to CAN-OUT3
6: sent to parameter channel 1
7: sent to parameter channel 2
8: received from CAN-IN1
9: received from CAN-IN2
10: received from CAN-IN3
11: received from parameter channel 1
12: received from parameter channel 2
C0361
1
2
3
4
5
6
7
8
9
10
11
12
/OD' 287
/OD' ,1
/OD' 287
/OD' 287
/OD' 287
/OD' 3287
/OD' 3287
/OD' ,1
/OD' ,1
/OD' ,1
/OD' 3,1
/OD' 3,1
g
0
{1 %}
100
CAN bus load
•
To ensure a perfect operation, the total bus
load (all connected devices) should be less
than 80%
1: all sent
2: all received
3: sent to CAN-OUT1
4: sent to CAN-OUT2
5: sent to CAN-OUT3
6: sent to parameter channel 1
7: sent to parameter channel 2
8: received from CAN-IN1
9: received from CAN-IN2
10: received from CAN-IN3
11: received from parameter channel 1
12: received from parameter channel 2
C0362
6W1E EWEMF
1.000
-32.000
{1.000 ms}
32.000
Time between two sync telegrams on the
system bus
C0363
6W1E EO55
1
1
{1}
5
1
0.8
µ
s
2
1.6
µ
s
3
2.4
µ
s
4
3.2
µ
s
5
4.0
µ
s
Correction value for C0362
[C0364]
&$1 DESJT
1000
see selection list 2
FIXED 0
Pre-operat. after operat.
Activate process data externally
Change over from pre-operation to operation
C0365
&$1 DESJT
g
0
1
Pre-operat. after operat.
Input signal CAN active
C0366
6W1E 5FRPO1RF
1
0
no sync response
1
sync response
CAN Sync Response
C0367
6W1E 5V ,'
128
1
{1}
256
CAN Sync Rx Identifier
C0368
6W1E 7V ,'
128
1
{1}
256
CAN Sync Tx Identifier
Summary of Contents for EVS9321-CS
Page 3: ...Operating Instructions EDB9300UES 00414796 Global Drive 9300 servo ...
Page 21: ...Technical data 3 8 BA9300SU EN 2 1 ...
Page 57: ...Installation 4 36 BA9300SU EN 2 1 ...
Page 73: ...During operation 6 4 BA9300SU EN 2 1 ...
Page 117: ...Troubleshooting and fault elimination 9 10 BA9300SU EN 2 1 ...
Page 119: ...Maintenance 10 2 BA9300SU EN 2 1 ...
Page 188: ...Appendix 11 69 BA9300SU EN 2 1 ...
Page 189: ...Appendix 11 70 BA9300SU EN 2 1 ...