Commissioning
5-10
BA9300SU EN 2.1
5.7
Change of the terminal assignment
(see also Chapter 8.3 ” Working with function blocks” )
If the configuration is changed via C0005, the assignment of all inputs and outputs will be overwritten
with the corresponding basic assignment. If necessary, the function assignment must be adapted
to the wiring.
Note!
Use the menu ” Terminal I/O” for the keypad 9371BB or the menu ” Terminal I/O” for Global Drive
Control or LEMOC2.
Stop!
To reassign an input, the signal source assigned before will not be overwritten! Remove unwanted
active links (see Chapter 8.3.3).
5.7.1
Freely assignable digital inputs
Five freely assignable digital inputs are available (X5/E1 ... X5/E5). It is possible to determine the
polarity for each input, i.e. the input is HIGH active or LOW active.
Change assignment:
Note!
Use the submenu ” DIGIN” for the keypad 9371BB or the submenu ” Digital inputs” for Global Drive
Control or LEMOC2.