Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - Other
SNMP Trap ID: 60
CIM Prefix: PLAT CIM ID: 0247
User Action:
Information only; no action is required
•
FQXSPMA0002N: Configuration Error for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
This message is for the use case when an implementation has detected a Memory DIMM configuration
error has been corrected.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Memory
SNMP Trap ID: 41
CIM Prefix: PLAT CIM ID: 0126
User Action:
Complete the following steps:
1. If the DIMM configuration was changed prior to this failure verify that the DIMMs are installed in the
correct population sequence.
2. RESEAT the DIMM that failed POST memory test and the DIMMs on adjacent slots if populated. Boot
to F1 setup and enable the DIMM. Reboot the system.
3. If the DIMMs have been upgraded just prior to the issue than update uEFI to the latest version.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
Service Action:
uefi_defined
•
FQXSPMA0005N: Subsystem [MemoryElementName] has insufficient memory for operation.
This message is for the use case when an implementation has detected that the usable Memory is
insufficient for operation.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Memory
SNMP Trap ID: 41
CIM Prefix: PLAT CIM ID: 0132
User Action:
Complete the following steps:
1. Ensure one or more DIMMs are installed in the server.
2. Resolve existing memory errors if they are present.
66
ThinkSystem SR850 V2 System Events Service Guide
Summary of Contents for ThinkSystem SR850 V2
Page 1: ...ThinkSystem SR850 V2 System Events Service Guide Machine Types 7D31 and 7D32 ...
Page 4: ...ii ThinkSystem SR850 V2 System Events Service Guide ...
Page 6: ...2 ThinkSystem SR850 V2 System Events Service Guide ...
Page 186: ...182 ThinkSystem SR850 V2 System Events Service Guide ...
Page 280: ...276 ThinkSystem SR850 V2 System Events Service Guide ...
Page 284: ...280 ThinkSystem SR850 V2 System Events Service Guide ...
Page 286: ...282 ThinkSystem SR850 V2 System Events Service Guide ...
Page 287: ......
Page 288: ......