Service Action:
Complete the following steps:
1. Check the log for a separate error related to an associatedPCIe device and resolve that error.
2. If the problem persists, move the affected adapter to a different slot. If a slot is not available or error recurs,
replace the affected adapter.
3. Inspect processor socket. If socket is damaged, replace the system board.
4. If problem persists, escalate to next level support.
•
FQXSFIO0020J: PCIe Isolation has occurred in PCIe slot [arg1]. The adapter may not operate
correctly.
Severity: Info
User Action:
Complete the following steps:
1. Check the log for a separate error related to an associated PCIe device and resolve that error.
2. Check the Lenovo support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
3. Check the system spec to make sure the PCIe that the PCIe device is installed in the compatible
PCIe slot and a compatible cable is used. If not, performance of this device might be impacted.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
Service Action:
Complete the following steps:
1. Check the log for a separate error related to an associated PCIe device and resolve that error.
2. Perform PD on PCIe error by moving the adapter to a different slot. If error follows the adapter, replace it.
3. Inspect processor socket. If socket is damaged, replace the system board.
4. If problem persists, escalate to next level support.
•
FQXSFIO0021J: PCIe Error Recovery has occurred in PCIe slot [arg1]. The adapter may not operate
correctly.
Severity: Info
User Action:
Complete the following steps:
1. Check the log for a separate error related to an associated PCIe device and resolve that error.
2. Check the Lenovo support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
3. Check the system spec to make sure that the PCIe device is installed in the compatible PCIe slot and
a compatible cable is used. If not, performance of this device might be impacted.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
.
199
Summary of Contents for ThinkSystem SR850 V2
Page 1: ...ThinkSystem SR850 V2 System Events Service Guide Machine Types 7D31 and 7D32 ...
Page 4: ...ii ThinkSystem SR850 V2 System Events Service Guide ...
Page 6: ...2 ThinkSystem SR850 V2 System Events Service Guide ...
Page 186: ...182 ThinkSystem SR850 V2 System Events Service Guide ...
Page 280: ...276 ThinkSystem SR850 V2 System Events Service Guide ...
Page 284: ...280 ThinkSystem SR850 V2 System Events Service Guide ...
Page 286: ...282 ThinkSystem SR850 V2 System Events Service Guide ...
Page 287: ......
Page 288: ......