Service Action:
1. Review PD Steps.
2. Clear RAID configuration using UEFI Setup (e.g. RAID utility in UEFI HII).
3. If problem persists, escalate to next level of support.
•
FQXPMER0003I: RAID configuration cleared successfully
Severity: Info
User Action:
Information only; no action is required.
Service Action:
n/a
•
FQXPMER0003M: Failed to erase internal storage drives
Severity: Error
User Action:
1. Ensure the proper connection of hard drives, backplane, and related cables.
2. Check if security function is enabled for the hard disk drives, if yes, disable that and retry the
operation.
3. Ensure device firmware is at the latest level.
4. Restart the system and retry the operation again.
5. If the problem persists, contact technical support.
Service Action:
1. Review PD Steps.
2. Remove the failed drives.
3. If problem persists, escalate to next level of support.
•
FQXPMER0004I: Internal storage drives erased successfully
Severity: Info
User Action:
Information only; no action is required.
Service Action:
n/a
•
FQXPMER0004M: Failed to clear system logs
Severity: Error
User Action:
1. Restart BMC via supported method and reboot the system.
2. Retry this operation again.
.
XClarity Provisioning Manager events
253
Summary of Contents for ThinkSystem SR850 V2
Page 1: ...ThinkSystem SR850 V2 System Events Service Guide Machine Types 7D31 and 7D32 ...
Page 4: ...ii ThinkSystem SR850 V2 System Events Service Guide ...
Page 6: ...2 ThinkSystem SR850 V2 System Events Service Guide ...
Page 186: ...182 ThinkSystem SR850 V2 System Events Service Guide ...
Page 280: ...276 ThinkSystem SR850 V2 System Events Service Guide ...
Page 284: ...280 ThinkSystem SR850 V2 System Events Service Guide ...
Page 286: ...282 ThinkSystem SR850 V2 System Events Service Guide ...
Page 287: ......
Page 288: ......