FQXSFMA0012I: The PFA of DIMM [arg1] has been deasserted.
Severity: Info
User Action:
Information only; no action is required.
Service Action:
Information only; no action is required.
•
FQXSFMA0012L: The [arg1] PFA Threshold limit has been exceeded on DIMM [arg2] at address
[arg3]. [arg4]
Severity: Warning
User Action:
Complete the following steps:
1. Reseat affected DIMM (Note: The event Log might contain a recent FQXSFMA0011I event denoting
detected change in DIMM population that could be related to this problem.)
2. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
memory error.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
Service Action:
Complete the following steps:
1. Verify PD steps.
2. Replace the DIMM identified by LightPath and/or event log entry if -V20 is NOT appended to the DIMM Serial
Number in the FFDC event log.
3. Replace system board.
4. If needed, replace processor.
5. If problem persists, escalate to next level support.
•
FQXSFMA0013I: Mirror Fail-over complete. DIMM [arg1] has failed over to to the mirrored copy.
[arg2]
Severity: Info
User Action:
Check the system-event log for uncorrected DIMM failures and replace those DIMMs.
Service Action:
Information only; no action is required.
•
FQXSFMA0014I: Memory spare copy initiated. [arg1]
Severity: Info
User Action:
Information only; no action is required.
.
207
Summary of Contents for ThinkSystem SR850 V2
Page 1: ...ThinkSystem SR850 V2 System Events Service Guide Machine Types 7D31 and 7D32 ...
Page 4: ...ii ThinkSystem SR850 V2 System Events Service Guide ...
Page 6: ...2 ThinkSystem SR850 V2 System Events Service Guide ...
Page 186: ...182 ThinkSystem SR850 V2 System Events Service Guide ...
Page 280: ...276 ThinkSystem SR850 V2 System Events Service Guide ...
Page 284: ...280 ThinkSystem SR850 V2 System Events Service Guide ...
Page 286: ...282 ThinkSystem SR850 V2 System Events Service Guide ...
Page 287: ......
Page 288: ......