Service Action:
uefi_defined
•
FQXSPPU0011N: An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has
asserted.
This message is for the use case when an SM BIOS Uncorrectable CPU complex error has asserted.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - CPU
SNMP Trap ID: 40
CIM Prefix: PLAT CIM ID: 0816
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or UEFI firmware update that applies to
this error.
2. Reboot system.
3. If problem persists, collect Service Data log.
4. Contact Lenovo Support.
Service Action:
uefi_defined
•
FQXSPPU2000I: [ProcessorElementName] in slot [SlotElementName] has been removed.
This message is for the use case when an implementation has detected a Processor has been Removed.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0035
User Action:
Information only; no action is required.
Service Action:
Information only; no action is required.
•
FQXSPPU2001I: An Over-Temperature Condition has been removed on [ProcessorElementName].
This message is for the use case when an implementation has detected a Over-Temperature Condition
has been Removed for Processor.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Temperature
.
119
Summary of Contents for ThinkSystem SR850 V2
Page 1: ...ThinkSystem SR850 V2 System Events Service Guide Machine Types 7D31 and 7D32 ...
Page 4: ...ii ThinkSystem SR850 V2 System Events Service Guide ...
Page 6: ...2 ThinkSystem SR850 V2 System Events Service Guide ...
Page 186: ...182 ThinkSystem SR850 V2 System Events Service Guide ...
Page 280: ...276 ThinkSystem SR850 V2 System Events Service Guide ...
Page 284: ...280 ThinkSystem SR850 V2 System Events Service Guide ...
Page 286: ...282 ThinkSystem SR850 V2 System Events Service Guide ...
Page 287: ......
Page 288: ......