FQXSFSR0003G: The number of boot attempts has been exceeded. No bootable device found.
Severity: Warning
User Action:
Complete the following steps:
1. Remove AC power from the system.
2. Connect at least one bootable device ot the system.
3. Connect AC power to the system.
4. Power on system and retry.
5. If the problem persists, collect Service Data logs.
6. Contact Lenovo Support.
Service Action:
Complete the following steps:
1. Review PD Steps.
2. If problem persists, escalate to next level support.
•
FQXSFTR0001L: An invalid date and time have been detected.
Severity: Warning
User Action:
Complete the following steps:
1. Check the XCC event logs. This event should immediately precede an FQXSFPW0001L error.
Resolve that event or any other battery related errors.
2. Use F1 Setup to reset date and time.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
Service Action:
Complete the following steps:
1. Review PD Steps.
2. Replace CMOS battery.
3. If problem persists then check Lenovo support site for an applicable service bulletin or firmware update that
applies to this error.
4. If problem persists, escalate to next level support.
240
ThinkSystem SR850 V2 System Events Service Guide
Summary of Contents for ThinkSystem SR850 V2
Page 1: ...ThinkSystem SR850 V2 System Events Service Guide Machine Types 7D31 and 7D32 ...
Page 4: ...ii ThinkSystem SR850 V2 System Events Service Guide ...
Page 6: ...2 ThinkSystem SR850 V2 System Events Service Guide ...
Page 186: ...182 ThinkSystem SR850 V2 System Events Service Guide ...
Page 280: ...276 ThinkSystem SR850 V2 System Events Service Guide ...
Page 284: ...280 ThinkSystem SR850 V2 System Events Service Guide ...
Page 286: ...282 ThinkSystem SR850 V2 System Events Service Guide ...
Page 287: ......
Page 288: ......