Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix:
PLAT
ID:
0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
•
806f060d-0407ffff : Array [ComputerSystemElementName] has failed. (Drive 7)
This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0407ffff or 0x806f060d0407ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix:
PLAT
ID:
0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
438
Lenovo System x3250 M5Installation and Service Guide
Summary of Contents for System x3250 M5
Page 1: ...Lenovo System x3250 M5 Installation and Service Guide Machine Type Type 5458 ...
Page 6: ...iv Lenovo System x3250 M5Installation and Service Guide ...
Page 36: ...22 Lenovo System x3250 M5Installation and Service Guide ...
Page 98: ...84 Lenovo System x3250 M5Installation and Service Guide ...
Page 122: ...108 Lenovo System x3250 M5Installation and Service Guide ...
Page 162: ...Figure 84 Server components 148 Lenovo System x3250 M5Installation and Service Guide ...
Page 546: ...532 Lenovo System x3250 M5Installation and Service Guide ...
Page 722: ...708 Lenovo System x3250 M5Installation and Service Guide ...
Page 738: ...724 Lenovo System x3250 M5Installation and Service Guide ...
Page 739: ......
Page 740: ......