SNMP Trap ID
11
CIM Information
Prefix:
PLAT
ID:
0480
User Response
1. Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system
board.
2. Replace the failing fan. (n = fan number)
•
80010204-1d05ffff : Numeric sensor [NumericSensorElementName] going low (lower critical)
has asserted. (Fan 5 Tach)
This message is for the use case when an implementation has detected a Lower Critical sensor going
low has asserted.
May also be shown as 800102041d05ffff or 0x800102041d05ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix:
PLAT
ID:
0480
User Response
1. Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system
board.
2. Replace the failing fan. (n = fan number)
•
80010701-0701ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted. (PCI Temp)
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107010701ffff or 0x800107010701ffff
Severity
356
Lenovo System x3250 M5Installation and Service Guide
Summary of Contents for System x3250 M5
Page 1: ...Lenovo System x3250 M5 Installation and Service Guide Machine Type Type 5458 ...
Page 6: ...iv Lenovo System x3250 M5Installation and Service Guide ...
Page 36: ...22 Lenovo System x3250 M5Installation and Service Guide ...
Page 98: ...84 Lenovo System x3250 M5Installation and Service Guide ...
Page 122: ...108 Lenovo System x3250 M5Installation and Service Guide ...
Page 162: ...Figure 84 Server components 148 Lenovo System x3250 M5Installation and Service Guide ...
Page 546: ...532 Lenovo System x3250 M5Installation and Service Guide ...
Page 722: ...708 Lenovo System x3250 M5Installation and Service Guide ...
Page 738: ...724 Lenovo System x3250 M5Installation and Service Guide ...
Page 739: ......
Page 740: ......