![LELY 5.1103.0010 Operator'S Manual Download Page 43](http://html1.mh-extra.com/html/lely/5-1103-0010/5-1103-0010_operators-manual_1874420043.webp)
Description and Operation
4-11
D-H023.0906EN
innovators in agriculture
4.2.7.3
The Processor
The processor is a box (a base and a cover) with pumps, valves, chambers
and electronics. It is installed on the milking robot frame behind the
intermediate panel and is attached to the processor installation bracket.
The processor has four main functions: to transport, mix, test and drain
the mixture. The processor pumps the milk from the sampler to the
processor and adds the Astri-Cell to the milk. When the test is done the
processor pumps the mixture to the sewer.
The processor has the following parts:
•
Pumps
•
Valves
•
Chambers
•
Control PCB.
The processor gets inputs from the sampler (electronic and milk
samples), the wall socket (Astri-Cell, water and compressed air) and the
MQC-II (via the CAN-bus connector).
The processor sends output to the sampler and the MQC. Results and
class attentions of the test can be found in the T4C software. Hardware-
related alarm messages can be found on the X-Link. The attentions lists
generated by T4C can be found on the X-Link.
4.2.7.4
The Wall Socket
The wall socket is installed behind the intermediate panel on the right
of the machine room above the Astri-pumps.
The wall socket joins the input of the water, Astri-Cell and compressed
air supply with the tube bundle that leads to the processor. The wall
socket has a adjustable pressure reducer for both the water and air
supply.
4.2.7.5
Anti-Freezing Facility
To prevent the fluid (milk, Astri-Cell, wasted mix) from freezing during
transportation and the test an anti-freezing facility is installed. This
facility has the following parts:
•
Temperature sensors, these are installed:
•
On the sampler PCB
•
In the milk tube bundle from the sampler to the processor
•
On the bottom of the processor.
•
Heater elements, these are installed:
•
On the box base of the sampler
•
On the processor
•
In the tube bundle from the sampler to the processor
•
In the waste/bleed tube bundle.
Summary of Contents for 5.1103.0010
Page 2: ...ii D H023 0906EN innovators in agriculture INTENTIONALLY BLANK...
Page 4: ...iv D H023 0906EN innovators in agriculture INTENTIONALLY BLANK...
Page 6: ...vi D H023 0906EN innovators in agriculture INTENTIONALLY BLANK...
Page 10: ...x D H023 0906EN innovators in agriculture INTENTIONALLY BLANK...
Page 16: ...xvi D H023 0906EN innovators in agriculture INTENTIONALLY BLANK...
Page 18: ...1 2 Introduction D H023 0906EN innovators in agriculture INTENTIONALLY BLANK...
Page 84: ...5 4 Installation D H023 0906EN innovators in agriculture Figure 14 Close the ball valve...
Page 86: ...5 6 Installation D H023 0906EN innovators in agriculture INTENTIONALLY BLANK...
Page 106: ...6 20 Operating Instructions D H023 0906EN innovators in agriculture INTENTIONALLY BLANK...
Page 122: ...7 16 Maintenance D H023 0906EN innovators in agriculture Figure 34 Remove the feed cover...
Page 131: ...Maintenance 7 25 D H023 0906EN innovators in agriculture Figure 38 Remove the cup cords...
Page 188: ...2 Glossary of Terms D H023 0906EN innovators in agriculture yd yard 36 inches...
Page 191: ...D H023 0906EN innovators in agriculture INTENTIONALLY BLANK...