![LELY 5.1103.0010 Operator'S Manual Download Page 110](http://html1.mh-extra.com/html/lely/5-1103-0010/5-1103-0010_operators-manual_1874420110.webp)
7-4
Maintenance
D-H023.0906EN
innovators in agriculture
7.3
Preparation
7.3.1
Switch OFF the Milking Robot
1.
Take the milking robot out of operation with the X-Link (page 6-1).
2.
On the X-Link, select:
•
Tab [System]
•
Button [Change view]
•
Button [Shutdown].
3.
Wait until the status of all services are not equal to Running.
The status of the services 'AGS' and 'ECS' remain 'Running'.
4.
Open the multiple function box (page 7-11).
WARNING
The air pressure remains in the robot until you release it.
5.
Set the circuit breakers (
fig. 23
, page 7-6) in the OFF position, one
by one from right (5) to left (1).
6.
Set the save-life switch (
2, fig. 22,
page 7-5) in the OFF position.
7.3.2
Switch ON the Milking Robot
1. Make
sure:
•
The main power supply is available and correctly connected to
the milking robot
•
The main water supply is available and correctly connected to
the milking robot
•
The compressed air supply is available and correctly connected
to the milking robot
•
The milking robot is correctly connected to the T4C network
2.
Open the multiple function box (page 7-11).
3.
Set the save-life switch (
2, fig. 22,
page 7-5) in the ON position.
4.
Set the automatic circuit breakers (
fig. 23
, page 7-6) in the ON
position, one by one from left (1) to right (5).
5.
Wait until the X-Link displays the [System] tab.
This takes approximately 30 seconds.
6.
Select button [Change view] and make sure:
•
the status of the AGS = 'Running'.
•
the status of ECS shows blank
•
the status of the other services is 'Init'.
7.
If these statuses are not as above:
1.
Select button [Shutdown]
2.
Wait about 5 seconds.
3.
Select button [Reset all]
Summary of Contents for 5.1103.0010
Page 2: ...ii D H023 0906EN innovators in agriculture INTENTIONALLY BLANK...
Page 4: ...iv D H023 0906EN innovators in agriculture INTENTIONALLY BLANK...
Page 6: ...vi D H023 0906EN innovators in agriculture INTENTIONALLY BLANK...
Page 10: ...x D H023 0906EN innovators in agriculture INTENTIONALLY BLANK...
Page 16: ...xvi D H023 0906EN innovators in agriculture INTENTIONALLY BLANK...
Page 18: ...1 2 Introduction D H023 0906EN innovators in agriculture INTENTIONALLY BLANK...
Page 84: ...5 4 Installation D H023 0906EN innovators in agriculture Figure 14 Close the ball valve...
Page 86: ...5 6 Installation D H023 0906EN innovators in agriculture INTENTIONALLY BLANK...
Page 106: ...6 20 Operating Instructions D H023 0906EN innovators in agriculture INTENTIONALLY BLANK...
Page 122: ...7 16 Maintenance D H023 0906EN innovators in agriculture Figure 34 Remove the feed cover...
Page 131: ...Maintenance 7 25 D H023 0906EN innovators in agriculture Figure 38 Remove the cup cords...
Page 188: ...2 Glossary of Terms D H023 0906EN innovators in agriculture yd yard 36 inches...
Page 191: ...D H023 0906EN innovators in agriculture INTENTIONALLY BLANK...