Spirit GE User Manual
- 26 -
LED INDICATOR LIGHTS
Three indicator lights on the LaserPro Spirit GE’s control panel are part of the system’s safety
interlock system.
DOOR
- The door light will illuminate when either the top lid or external pass through doors on
the LaserPro Spirit GE are open or improperly closed.
POWER
- The power light will illuminate when the LaserPro Spirit GE is powered on.
LASER
- The laser light will illuminate when the laser is active and in operation.
WARNING
•
DO NOT
attempt to remove or modify any component of the safety interlock
system.
•
If at any time, any of the access doors are open and the “laser” LED is
illuminated,
IMMEDIATELY
unplugs the laser system and contact GCC
technical support for service instructions.
•
DO NOT
operate the laser system if any component of the safety system is
malfunctioning.
NOTE
There is an 8 second warm up period after the door LED is triggered for systems
equipped with Synrad laser tubes. i.e. opening the top lid or the external pass through
doors of the machine. Operator must wait for 8 seconds before the laser tube can begin
to work.
LED Indicator Lights
LCD Display Screen
Function Buttons
Directional and