5: Commands and Levels
PremierWave® 2050 Enterprise Wi-Fi® IoT Module Command Reference
81
<interface name> = Interface name
clrscrn
Clears the screen.
exit
Exits to the configuration level.
remove all
Removes all entries from the ARP cache.
remove ip
<IP address>
<Interface name>
Removes an entry from the ARP cache. <ip address> =
address of the entry being removed. <interface name> =
Interface name
show cache
Displays the ARP cache table.
show history
Displays the last 20 commands entered during the current
CLI session.
write
Stores the current configuration in permanent memory.
bluetooth (config-bluetooth) level commands
clrscrn
Clears the screen.
exit
Returns to the config level.
show
Displays the current configuration.
show history
Displays the last 20 commands entered during the current
CLI session.
show statistics
Displays the Bluetooth statistics.
state disable
Disables Bluetooth.
state enable
Enables Bluetooth.
write
Stores the current configuration in permanent memory.
bluetooth serial 1 (bluetooth-line:1) level commands
auto show statistics
Continuously displays line statistics.
bluetooth serial
<line>
Enters the bluetooth serial level. <line> = number of the
line (bluetooth serial port) to be configured.
clear line counters
Sets the serial counters to zero.
clrscrn
Clears the screen.
command mode always
Sets the current line to always be in command mode.
command mode echo serial string disable
Disables user-defined serial boot string to be echoed in
the CLI.
command mode echo serial string enable
Enables user-defined serial boot string to be echoed in
the CLI.
command mode serial string
Enables user to enter a custom string at boot time to enter
command mode.
command mode serial string
<string>
Sets a string that can be entered at boot time to enter
command mode. <string> = text with possible binary
characters. Within [] use binary decimal up to 255 or hex
up to 0xFF. Within {} specify decimal milliseconds time
delay.
command mode signon message
<string>
Sets a sign-on message that is sent from the serial port
when the device boots and when the line is in command
mode. <string> = text with possible binary characters.
Within [] use binary decimal up to 255 or hex up to 0xFF.
command mode wait time
<milliseconds>
Sets boot-up wait time for command mode serial string.
<milliseconds> = wait time.
default line mode
Restores the default line mode.
default threshold
Restores the factory default threshold.
exit
Exits to the enable level