5: Commands and Levels
PremierWave® 2050 Enterprise Wi-Fi® IoT Module Command Reference
358
exit
Exits to the next higher level.
key
<hexadecimal>
Sets WEP key. Each byte is represented by two adjacent
hex digits. Bytes may run together or be separated by
optional punctuation: 123ABC "12 3A BC" 12,3A,BC
12.3a.bc 12:3a:bc Note that quotes must enclose the val-
ue if it contains spaces.
key text
<text>
Sets WEP key. Each byte is represented by a single
character. Note that quotes must enclose the value if it
contains spaces.
no key
Removes WEP key.
show
Shows the current configuration.
show history
Displays the last 20 commands entered during the current
CLI session.
write
Stores the current configuration in permanent memory.
line 1 (line:1) level commands
auto show statistics
Continuously displays line statistics.
baud rate
<bits per second>
Sets the line speed. <bits per second> = the speed.
Standard speeds include 1200, 2400, 4800, 9600, 19200,
and so on.
bluetooth serial
<line>
Enters the bluetooth serial level. <line> = number of the
line (bluetooth serial port) to be configured.
clear line counters
Sets the serial counters to zero.
clrscrn
Clears the screen.
command mode always
Sets the current line to always be in command mode.
command mode echo serial string disable
Disables user-defined serial boot string to be echoed in
the CLI.
command mode echo serial string enable
Enables user-defined serial boot string to be echoed in
the CLI.
command mode serial string
Enables user to enter a custom string at boot time to enter
command mode.
command mode serial string
<string>
Sets a string that can be entered at boot time to enter
command mode. <string> = text with possible binary
characters. Within [] use binary decimal up to 255 or hex
up to 0xFF. Within {} specify decimal milliseconds time
delay.
command mode signon message
<string>
Sets a sign-on message that is sent from the serial port
when the device boots and when the line is in command
mode. <string> = text with possible binary characters.
Within [] use binary decimal up to 255 or hex up to 0xFF.
command mode wait time
<milliseconds>
Sets boot-up wait time for command mode serial string.
<milliseconds> = wait time.
configure current settings
Configures line with the current value of settings.
data bits 7
Uses seven bits for data on the line.
data bits 8
Uses eight bits for data on the line.
default baud rate
Restores the default speed of 9600 bits per second.
default data bits
Restores the default of eight data bits.
default flow control
Restores the default of no flow control.
default full duplex termination
Restores the default termination on this line.
default parity
Restores the default of no parity.