5: Commands and Levels
PremierWave® 2050 Enterprise Wi-Fi® IoT Module Command Reference
361
line 2 (line:2) level commands
auto show statistics
Continuously displays line statistics.
baud rate
<bits per second>
Sets the line speed. <bits per second> = the speed.
Standard speeds include 1200, 2400, 4800, 9600, 19200,
and so on.
bluetooth serial
<line>
Enters the bluetooth serial level. <line> = number of the
line (bluetooth serial port) to be configured.
clear line counters
Sets the serial counters to zero.
clrscrn
Clears the screen.
command mode always
Sets the current line to always be in command mode.
command mode echo serial string disable
Disables user-defined serial boot string to be echoed in
the CLI.
command mode echo serial string enable
Enables user-defined serial boot string to be echoed in
the CLI.
command mode serial string
Enables user to enter a custom string at boot time to enter
command mode.
command mode serial string
<string>
Sets a string that can be entered at boot time to enter
command mode. <string> = text with possible binary
characters. Within [] use binary decimal up to 255 or hex
up to 0xFF. Within {} specify decimal milliseconds time
delay.
command mode signon message
<string>
Sets a sign-on message that is sent from the serial port
when the device boots and when the line is in command
mode. <string> = text with possible binary characters.
Within [] use binary decimal up to 255 or hex up to 0xFF.
command mode wait time
<milliseconds>
Sets boot-up wait time for command mode serial string.
<milliseconds> = wait time.
configure current settings
Configures line with the current value of settings.
data bits 7
Uses seven bits for data on the line.
data bits 8
Uses eight bits for data on the line.
default baud rate
Restores the default speed of 9600 bits per second.
default data bits
Restores the default of eight data bits.
default flow control
Restores the default of no flow control.
default full duplex termination
Restores the default termination on this line.
default parity
Restores the default of no parity.
default stop bits
Restores the default of one stop bit.
default threshold
Restores the factory default threshold.
default xoff char
Restores the default xoff character on this line.
default xon char
Restores the default xon character on this line.
exit
Exits to the enable level
flow control hardware
Uses hardware (RTS/CTS) flow control on the line.
flow control none
Does not provide flow control on the line.
flow control software
Uses software (xon/xoff characters) flow control on the
line.
full duplex termination disabled
Disables line termination.
full duplex termination termination on rx
Sets line termination on Rx only.
full duplex termination termination on tx
Sets line termination on Tx only.
full duplex termination termination on tx and rx
Sets line termination on Tx and Rx.