5: Commands and Levels
PremierWave® 2050 Enterprise Wi-Fi® IoT Module Command Reference
359
default stop bits
Restores the default of one stop bit.
default threshold
Restores the factory default threshold.
default xoff char
Restores the default xoff character on this line.
default xon char
Restores the default xon character on this line.
exit
Exits to the enable level
flow control hardware
Uses hardware (RTS/CTS) flow control on the line.
flow control none
Does not provide flow control on the line.
flow control software
Uses software (xon/xoff characters) flow control on the
line.
full duplex termination disabled
Disables line termination.
full duplex termination termination on rx
Sets line termination on Rx only.
full duplex termination termination on tx
Sets line termination on Tx only.
full duplex termination termination on tx and rx
Sets line termination on Tx and Rx.
gap timer
<milliseconds>
Sets the gap timer in milliseconds. If some data has been
received, it will be forwarded after this time since the last
character.
interface rs232
Sets the line interface to RS232.
interface rs485 full-duplex
Sets the line interface to RS485 in full-duplex mode.
interface rs485 half-duplex
Sets the line interface to RS485 in half-duplex mode.
kill session
Kills command mode session on the Line
line
<line>
Enters the line level. <line> = number of the line (serial
port) to be configured.
name
<text>
Sets the name for this line.
no clear line counters
Restores the serial counters to the aggregate values.
no command mode
Disables command mode for the current line.
no command mode signon message
Clears the signon message displayed at boot time and
when entering command mode.
no gap timer
Removes the gap timer, so forwarding depends on the
line speed.
no name
Removes the name of this line.
parity even
Uses a parity bit on the line for even parity.
parity none
Does not use a parity bit on the line.
parity odd
Uses a parity bit on the line for odd parity.
protocol modbus ascii
Applies Modbus ASCII protocol on the line.
protocol modbus rtu
Applies Modbus RTU protocol on the line.
protocol none
Uses no protocol on the line.
protocol tunnel
Applies tunnel protocol on the line.
reassert
Asserts line status with current configured values.
show
Displays the current status.
show command mode
Shows the command mode settings for the current line.
show history
Displays the last 20 commands entered during the current
CLI session.
show line
Displays the current configuration.
show statistics
Shows the line statistics.
state disable