5: Commands and Levels
PremierWave® 2050 Enterprise Wi-Fi® IoT Module Command Reference
419
the CLI.
command mode serial string
Enables user to enter a custom string at boot time to enter
command mode.
command mode serial string
<string>
Sets a string that can be entered at boot time to enter
command mode. <string> = text with possible binary
characters. Within [] use binary decimal up to 255 or hex
up to 0xFF. Within {} specify decimal milliseconds time
delay.
command mode signon message
<string>
Sets a sign-on message that is sent from the serial port
when the device boots and when the line is in command
mode. <string> = text with possible binary characters.
Within [] use binary decimal up to 255 or hex up to 0xFF.
command mode wait time
<milliseconds>
Sets boot-up wait time for command mode serial string.
<milliseconds> = wait time.
data bits 7
Uses seven bits for data on the line.
data bits 8
Uses eight bits for data on the line.
default baud rate
Restores the default speed of 115200 bits per second.
default data bits
Restores the default of eight data bits.
default flow control
Restores the default of hardware (RTS/CTS) flow control.
default line mode
Restores the default usb line mode.
default parity
Restores the default of no parity.
default stop bits
Restores the default of one stop bit.
default threshold
Restores the factory default threshold.
default xoff char
Restores the default xoff character on this line.
default xon char
Restores the default xon character on this line.
exit
Exits to the enable level
flow control hardware
Uses hardware (RTS/CTS) flow control on the line.
flow control none
Does not provide flow control on the line.
flow control software
Uses software (xon/xoff characters) flow control on the
line.
gap timer
<milliseconds>
Sets the gap timer in milliseconds. If some data has been
received, it will be forwarded after this time since the last
character.
interface usb-cdc-acm
Sets the usb line interface to USB-CDC-ACM.
kill session
Kills command mode session on the Line
line
<line>
Enters the line level. <line> = number of the line (serial
port) to be configured.
line mode ethernet device
Sets the usb line to ethernet device mode.
line mode host
Sets the usb line to host mode.
line mode serial device
Sets the usb line to serial device mode.
name
<text>
Sets the name for this usb line.
no clear line counters
Restores the serial counters to the aggregate values.
no command mode
Disables command mode for the current line.
no command mode signon message
Clears the signon message displayed at boot time and
when entering command mode.
no gap timer
Removes the gap timer, so forwarding depends on the
usb line speed.
no name
Removes the name of this usb line.