Installation
32
Figure 2-11. Console Assembly Installation
14. Remove power cord from motor pan and plug into
receptacle at front of treadmill.
15. Run the Upper Wire Harness behind the Elevation Motor
(opposite screw end, Figure 2-13) and connect it to the
Motor Control Board as appropriate:
•
Attach ground wire from base grounding point (Figure
2-12) to corresponding colored ground wire on Upper
Wire Harness.
•
PWM: Connect to 9-pin connector.
•
SCR: Connect to 6-pin and 2-pin connectors.
Stud (both sides)
Keyway (both sides)
Pulse cable
Ribbon Cable
Upper Wire Harness