AUTOMATIC AIR PURGE 

 

This  device purges the  air  from  the  piping,  helps  to  prevent  cavitation  at  the  inlet  of  the  circulating pump  and also inhibits corrosion.  It also 
minimizes new water intake into the system. The installation of an automatic air purge prevents the accumulation of air in the heating loop. To 
function properly, it must be installed at the highest point in the heating loop thus eliminating any air accumulation during the putting in service 
of the system and maintaining afterwards the water-tightness of the system. 

 

 

COMBINED PRESSURE REGULATOR AND PRESSURE RELIEF VALVE  

The installation of a combined pressure regulator and pressure relief valve must be done in conformance with all codes and local regulations. 
This module must automatically maintain an adequate volume of water and optimum pressure in the heating loop of a  max. 124,1kPa (18psi) 
and be provided with a backflow preventer.  

 

 

ZONING WITH CIRCULATING PUMPS  

The suggested location for each motorized zone pump is on the supply side of the heating loop, the expansion tank being situated between 
the  boiler  and  each  zone  pump.  A  backflow  preventer  must  be  installed  in  each  zone, at  the  outlet  of  each  pump,  to  prevent  a  backflow  of 
heated water to the zones without a heating demand. 

 

 

ZONING WITH MOTORIZED VALVES  

The suggested location for each motorized zone valve is on the supply side of the heating loop, the expansion tank being situated between the 
boiler and each zone valve. However, the installation of motorized zone valves on the return of each zone is also acceptable  if the circulating 
pump is situated downstream from the valves on the main return to the boiler. It is recommended to use low-pressure drop motorized zone 
valves in zoning applications. 

 

 

MAIN CIRCULATING PUMP 

 

The suggested location of the main circulating pump is on the supply side of the heating loop, the expansion tank being situated between the 
boiler and the pump.  

 

 
 
 
 

 

ACCESSOIRES MAJEURS ET DE PROTECTION :  

Le circuit externe de la chaudière 

Bilovax LS150

 

doit être pourvu d’une soupape de surpression (fournie avec), d’un vase d’expansion, d’une 

pompe  de  circulation,  d’un  module  régulateur  de  pression  et  soupape  de  surpression  combinés  pour  l’alimentation  en  eau  neuve,  d’un 
manomètre-

thermomètre combiné et d’un robinet de vidange.  Aussi prévoir une zone de délestage en cas de surchauffe de la chaudière. La 

zone de délestage de la chaudière 

Bilovax LS150

 est de plus de 20 000 BTU/h ou 6 kW/h. Tous ces régulateurs et éléments  de protection 

sont requis pour l’opération sécuritaire de la chaudière 

Bilovax LS150

.  

 
CLAPET ANTIRETOUR 

Si le système de chauffage utilise une seule pompe, un clapet antiretour doit être installé pour empêcher la circulation par gravité et les pertes 
de chaleur inutiles durant les périodes sans demande de chauffage. Aussi installer des clapets antiretour pour chaque zone lorsq

ue l’on utilise 

des pompes de circulation pour faire le zonage. 

 

SOUPAPE DE SURPRESSION 

Une soupape de surpression est fournie avec la chaudière et il s’agit d’une composante de sécurité et non de régulation. Le point de déclenchement de la 
soupape est fixé à 207 kPa (30psi), ce qui est conforme à la norme (ASME Boiler and Pressure Vessel Code)

 

pour limiter la pression maximum en service 

de la chaudière. La capacité de la soupape de surpression en BTU/heure est égale ou supérieure à la puissance calorifique inscrite sur la plaque signalétique 
de la chaudière. Lors de l’installation, raccorder  la sortie de la soupape à un tuyau d’évacuation en cuivre non fileté dirigé vers le plancher et du même 
diamètre que la sortie de la soupape dont l’extrémité sera à 15 cm (6") au plus du siphon de sol et bien éloigné de tout appareil ou composant électrique. 
Aucun autre robinet, soupape ou clapet ne doit être installé sur ce tuyau d’évacuation. Bien s’assurer que le tuyau

 

d’évacuation se vide complètement lors de 

l’opération de la soupape et veiller à le protéger contre le gel. L’installation des soupapes de surpression est aussi régie par les autorités locales. 

 

 

MAINTIEN DE LA PRESSION INTERNE PAR UN VASE DE DILATATION 

Le vase de dilatation à membrane sous pression préréglée aide à maintenir une pression constante à l’intérieur de la boucle de chauffage afin de respecter les 
critères de fonctionnement de tous ses composants malgré les variations de température et de volume de l’eau à l’intérieur de celle-ci. Le vase de dilatation 
doit être capable d’absorber le volume d’eau requis lorsque la température de l’eau dans la boucle de chauffage est à son maximum tout en maintenant la 
pression optimale de calcul et doit, en même temps, le faire quand la boucle de chauffage est froide. Le point de raccordement du vase de dilatation doit être 
soigneusement choisi pour éviter que la fermeture de clapets ou de robinets ne l’isole de la chaudière ou de toute autre partie de la boucle de chauffage. Le 
vase de dilatation doit être situé du côté alimentation de la pompe de circulation qui doit être installée le plus près possible de la chaudière, en amont ou en 
aval.  Le  vase  de  dilatation  doit  travailler  conjointement  avec  le  module  régulateur  de  pression  et  soupape  de  surpression  combinés  afin  de  maintenir  un 
volume d’eau adéquat dans la boucle de chauffage ainsi qu’une pression optimale de 124,1 kPa (18psi). 

 

 
 
 
 
 
 
 

Page 8 

Page 39 

Summary of Contents for LS150

Page 1: ...LS150 MANUEL D INSTALLATION D ENTRETIEN ET D UTILISATION INSTALLATION MAINTENANCE AND USER MANUAL English page 32 SEP 18 2015 ...

Page 2: ... INSTRUCTIONS CONTENUES DANS CE MANUEL NE SONT PAS SUIVIES À LA LETTRE CECI PEUT CAUSER UNE EXPLOSION OU UN INCENDIE QUI POURRAIT ENTRAÎNER LA MORT OU DES LÉSIONS CORPORELLES ET OU DES DOMMAGES MATÉRIELS IMPORTANTS MISE EN GARDE UNE INSTALLATION DES AJUSTEMENTS DU SERVICE OU DE L ENTRETIEN INCORRECTS PEUVENT CAUSER UNE EXPLOSION OU UN INCENDIE QUI POURRAIT ENTRAÎNER LA MORT OU DES LÉSIONS CORPOREL...

Page 3: ...mbreuses années Ce manuel contient les directives et les mesures de sécurité nécessaires à l installation à la mise en service à l entretien et à l utilisation de ce type d appareil INFORMATIONS GÉNÉRALES Mise en garde Il est d une importance capitale de respecter les dégagements minimaux aux matériaux combustibles comme indiqué sur la plaque d homologation afin d éviter un incendie ou une explosi...

Page 4: ... C or more ELECTRICAL SUPPLY OF THE BOILER The electrical wiring to the boiler must conform to the Canadian Electrical Code and to the local codes these having precedence in certain municipalities In the case of the wood heating Bilovax LS150 provide an electrical circuit of 120Vac 1ph 60Hz protected by a breaker of the appropriate capacity In the case of the Dual Energy Bilovax LS150 provide an e...

Page 5: ...from the boiler by lightly pulling on the lever of the safety relief valve Purge all the air from the heating loop by pressing on the valve stem of the air purge remove cap If air is present wait until clear water is evacuated before releasing the lever of the safety relief valve or the air purge valve stem Check that the circulating pump and the combustion air damper are both fully functional SEC...

Page 6: ...e loading door of the Bilovax LS150 slowly and carefully to the first detent without using any force against the safety latch Pull on the smoke bypass damper lever to evacuate all the smoke and unburned gases from the combustion chamber After 30 seconds to a minute open the loading door fully past the second detent and put a full load of wood in the Bilovax LS150 on the embers Then firmly close th...

Page 7: ... also to help to increase the life of the system A system of filtration can also be recommended when there is a high rate of particles a temperature above 5 o C 40 o F must always be maintained in the room where the boiler is installed to protect it from freezing With a mixture of water and 54 propylene glycol or ethylene glycol it is possible to protect the boiler and the heating loop piping up t...

Page 8: ...constant supply temperature less the return temperature from the heating loop For example a boiler may have a supply temperature of 180 F and a return temperature of 160 F the T is then 20 F 11 C 180 F 160 F T or TEMPERATURE DROP THROUGH THE HEATING LOOP Type of system Boiler Supply Temperature Boiler Return Temperature T or Temperature Drop Through Boiler Baseboards 190 to 140 F 88 60 C 170 to 12...

Page 9: ...TU h ou 6 kW h Tous ces régulateurs et éléments de protection sont requis pour l opération sécuritaire de la chaudière Bilovax LS150 CLAPET ANTIRETOUR Si le système de chauffage utilise une seule pompe un clapet antiretour doit être installé pour empêcher la circulation par gravité et les pertes de chaleur inutiles durant les périodes sans demande de chauffage Aussi installer des clapets antiretou...

Page 10: ...use It is preferable that the piping not go through an unheated space on the other hand if this cannot be avoided it is most important to thermally insulate the piping and to install heating cables to eliminate any and all risks of freezing of the pipes Even where the piping of the heating loop goes through a heated space it is a good practice to insulate the pipes to minimize heat losses It is re...

Page 11: ...ion constante moins la température du retour de l eau de chauffage Par exemple une chaudière peut avoir une température d alimentation de 180 F Avec une température de retour de 160 F le T est donc de 20 F 11 C 180 F 160 F T ou BAISSE DE TEMPÉRATURE À TRAVERS LA BOUCLE DE CHAUFFAGE Type de système Température d alimentation Température de retour T ou Baisse de température Plinthes chauffantes 190 ...

Page 12: ...urité à deux étages d ouverture tirez sur le levier du clapet de dérivation pour évacuer toute la fumée et tous les gaz non brûlés après 30 secondes à une minute ouvrez toute grande la porte et mettez une pleine charge de bois dans le Bilovax sur les tisons et la braise et ensuite refermez le clapet de dérivation et la porte Le cycle normal de combustion devrait redémarrer dans un court délai Avec...

Page 13: ...r automatique on doit enlever le capuchon Si de l air sort attendez qu un peu d eau sorte avant de relâcher le levier de la soupape de surpression ou la tige du purgeur d air automatique Pourcentages typiques dans un mélange eau antigel propylène et glycol Dowfrost qui protégera du gel la chaudière et la tuyauterie de la boucle de chauffage aux températures mentionnées Température O C O F d antige...

Page 14: ...N OR WARNING Please understand the full meaning of the following words DANGER CAUTION or WARNING These words are associated with safety and it s symbols You will find them in the manual in the following manner DANGER The word DANGER indicates the gravest of dangers those that will result in loss of life or major injuries and or serious property damages CAUTION The word CAUTION indicates a danger w...

Page 15: ...t nettoyage de la chambre de combustion IMPORTANT Inspecter la chambre de combustion en vérifiant que les tuiles réfractaires sont en bon état et bien assujetties Si des tuiles réfractaires sont endommagées remplacez les par des tuiles neuves Pour ce faire enlevez le panneau en tôle avant de la chaudière la façade démontable de la chambre de combustion et remplacez les tuiles endommagées Pour comm...

Page 16: ...n pour le mode chauffage au bois et aussi pour le chauffage électrique où chaque élément possède aussi sa lampe témoin Avec l option biénergie et les interrupteurs de modes il est possible de chauffer seulement au bois de chauffer seulement avec les éléments électriques ou les deux modes ensemble Avec les deux modes en fonction cette option permet de ne pas manquer de chauffage lorsque le bois est...

Page 17: ...ses différents composants Surtout ne pas oublier que tous les composants du système peuvent affecter le fonctionnement sécuritaire de l appareil et que les techniciens doivent prendre connaissance des particularités de l appareil avant de procéder à son dépannage MISE EN GARDE Si le technicien désire utiliser un cavalier pour faire dérivation autour d un composant qu il veut isoler afin de faire u...

Page 18: ...E ACCORDING TO STANDARD CODE GAUGE C A SHUT OFF VALVE ELECTRIC CONTROL LINE ROOM TEMPERATURE CONTROLLER THERMOSTAT SEVERAL RELAY CONTACTS EXPANSION TANK NO 60 MINIMUM HEATING COIL AIR SEPARATOR COMPRISING AN AIR PURGE LEGEND TUYAUTERIE D ALIMENTATION D EAU CHAUDE TUYAUTERIE DE RETOUR D EAU FROIDE UNION DE BRIDE ROBINET À VANNE CLAPET DE RETENU DOUBLE ROBINET DE VIDANGE AVEC RACCORD POUR BOYAU ET B...

Page 19: ...ECTION TO A RADIANT FLOOR P2 Page 18 Page 29 Identification des borniers du panneau électrique Identification of electrical panel terminals IMPORTANT Les pompes P1 et P2 doivent être alimentés par l entrée électrique du bâtiment et protégées par un circuit d un maximum de 15 AMP NE JAMAIS RACCORDER P1 ET P2 DIRECTEMENT À LA CHAUDIÈRE The pumps P1 and P2 must be powered by the electrical input of t...

Page 20: ...SEBOARD 2 PLINTHE BASEBOARD 3 EXP P2 P1 Page 28 Page 19 240 VCA VAC 120 VCA VAC SCHEMA ÉLECTRIQUE CHAUDIÈRE LS150 bois électrique WIRING SCHEMATIC LS150 BOILER wood electric L1 L2 N L1 T1 M3 M4 EL 1 T3 L3 M3 M4 EL 2 L2 T2 M3 M4 EL3 T4 L4 M3 M4 EL 4 FUSIBLE FUSE 15 AMP AQUASTAT L6006A1145 INTERRUPTEUR ÉLECTRIQUE ELECTRIC SWITCH R HAUTE LIMITE HIGH LIMIT W B 200 ZONE DE DÉLESTAGE DIVERTING ZONE 120 ...

Page 21: ...the back of the boiler T T T Zone 1 Zone 2 S C EXP P2 P1 T 240 VCA VAC L1 SCHEMA ÉLECTRIQUE CHAUDIÈRE LS150 bois électrique WIRING SCHEMATIC LS150 BOILER wood electric N L1 120 VCA VAC L2 C1 S1 C1 S2 C1 S1 C1 L1 T1 M3 M4 EL 1 T3 L3 M3 M4 EL 2 L2 T2 M3 M4 EL3 T4 L4 ZONE DE DÉLESTAGE DIVERTING ZONE AQUASTAT L6006A1145 INTERRUPTEUR ÉLECTRIQUE ELECTRIC SWITCH A1 C1 A2 FUSIBLE FUSE 15 AMP B R W 200 120...

Page 22: ...EMENT AVEC CONTRÔLE DE BASSE TEMPÉRATURE RACCORDÉ À LA CHAUDIÈRE THE SETTING OF THE OTHER HEATING SYSTEM MUST BE AT A MINIMUM OF 150 f TO AVOID TURNOFF OF THE SUPPLY PUMPS P2 connected to the aquastat at the back of the boiler P1 CONTINUING CIRCULATION FOR MIXING OF WATER P2 CONNECTION WITH LOW TEMPERATURE CONTROL CONNECTED TO BOILER ÉCHELLE AUCUNE SCALE NONE RÈGLAGE MINIMUM À 150 F MINIMUM SETTIN...

Page 23: ...anne résultant d une installation réparation entretien ou usage non conforme à la réglementation en vigueur ou 3 Vice ou panne résultant d une installation réparation entretien ou usage négligent ou résultant d un bris causé par le propriétaire ou entretien incorrect mauvais usage accident ou modification ou 4 Vice ou panne causé par le gel les inondations et les intempéries ou 5 Installation sans...

Page 24: ...y or 12 That the serial number has been altered or erased from the nameplate by persons unknown Limitations L S Bilodeau inc will not be liable for incidental or consequential damages loss or inconvenience of any sort directly or indirectly pursuant to a failure or breakdown of the Bilovax LS150 boiler All implied warranties of merchantability and fitness for a particular use or purpose are hereby...

Reviews: