L.S. Bilodeau inc. 

281 Route 108 Est, Saint-Éphrem-de-Beauce, Quebec G0M 1R0 

 

 

 

 

 

Tel.: 418 484-

2013 ▪ Fax: 418 484-2014 ▪ 

www.lsbilodeau.com

 

 

 

LS150 

 

2015-09-18

 

 

 

Illustration 1 

 

Modèle 

Hauteur 

Largeur 

Profondeur 

Poids 

Bilovax LS150 

129,5 cm 
(51") 

81,9 cm 
(32-1/4") 

84,7cm (33-3/8") c/a prise d’air 
primaire 

452 kg (995 lb) 
 

Bilovax LS150-E18 
kW 
Bilovax LS150-E24 
kW biénergie 

129,5 cm 
(51") 

96,2 cm 
(37-7/8") 

84,7cm (33-3/8") c/a prise d’air 
primaire 

461 kg (1 015 lb) 

 
Modèle biénergie illustré 

 

 

Illustration 2 

 
 
 
 
 

 

Typical percentages of a mix of water / propylene glycol antifreeze ("Dowfrost") in boilers and heating loop piping to 
protect them from freezing at the given temperatures. 

                          Temperature 
               

O

 C                                             

O

 F 

% of antifreeze in solution with water to prevent freezing at the 
different temperatures shown 

              -12                                            (10) 
              -18                                            (  0) 

                           29% 
                           36% 

              -23                                           (-10) 
              -29                                           (-20)     
              -34                                           (-30) 

                           42% 
                           46% 
                           50% 

              -40                                           (-40)    
              -46                                           (-50)    

                           54% 
                           57%  

 
 

CAUTION 

The loading door of the 

Bilovax LS150

 is equiped with a two-stage opening safety door latch.  This design has been chosen to 

prevent,  during  the  opening  of  the  loading  door,  a  flashback  of  combustion  gases  from  occurring  if  there  is  a  sudden  and 
uncontrolled  draft.    Do  not  attempt  to  force  or  modify  in  any  way,  shape  or  form  the  safety  door  latch  which  assures  the  safe 
functioning of the appliance.  The failure to heed this caution could cause an explosion or fire which could result in loss of life or 
major injuries and/or serious property damage. 

 

 
LIGHTING INSTRUCTIONS: 

Open the loading door and inspect the combustion chamber to make sure that there is no ash on the bottom. If there are ashes, sweep them 
into the built-in ashtray. Place crumpled sheets of dry newspaper on the bottom and cover them with kindling and a sufficient quantity of dry 
logs 45 cm (18") long maximum, up to the middle of the combustion chamber. Light the newspaper whilst keeping the loading door half-open.  
Make sure that the fire is well lit before closing the loading door. After an hour or so, crack open the loading door of the 

Bilovax LS150

 slowly 

and carefully to the first detent without using any force against the safety latch. Pull on the smoke bypass damper lever to  evacuate all the 
smoke and unburned gases from the combustion chamber. 

After 30 seconds to a minute,

 open the loading door fully, past the second detent, 

and put a full load of wood in the 

Bilovax LS150

 on the embers. Then firmly close the bypass damper and the loading door, this should allow 

for a wood-burning cycle of two to three 

hours depending on the type of wood and it’s dryness. As much as possible, always use dry wood for 

a better efficiency and less chance of sooting up the appliance and the chimney. If it is not desirable to prolong the heating cycle beyond three 
hours, simply let the fire die down by itself in the boiler.

  

 

Weekly maintenance during the heating season: 

At  least  once  a  week  during  the  heating  season,  open  the access  panel  on  top  of  the  boiler  to  inspect  and,  if  necessary,  clea n  the  smoke 
passages situated above the combustion chamber, (see figure 11). If there are any ashes in the combustion chamber, sweep them into the 
ashtray. Once the ashtray is full, empty the ashes into a metal container with a hermetic lid and then store the container outdoors. 

 

Preparations for stopping the boiler during the summer period

In temperate regions, the 

Bilovax LS150

 boiler can continue to operate during the cold spells of early to mid-spring. Before stopping the boiler 

for  the  summer,  open  the  access  panel  on  top  of  the  boiler  to  inspect  and,  if  necessary,  clean  the  smoke  passages  situated  above  the 
combustion chamber (see figure 11), If there are any ashes in the combustion chamber, sweep them into the ashtray. Dump the ashes from 
the  ashtray  into  a  metal  container  with  a  hermetic  lid  and  then  store  the  container  outdoors.  Also  make  sure  that  the  refractory  tiles  are 
undamaged  and  all  in  their  proper  place.  If  some  refractory  tiles  are  damaged,  they  must  be  replaced  by  new  tiles.  The  smoke  pipe  / 
connector and chimney must also be inspected and swept before stopping the boiler for the summer period. 

 

 

FIGURE 11  

 

 

HOMOLOGUÉ 

VOIR PLAQUE 

DU FABRICANT 

CERTIFIED SEE 

NAMEPLATE OF 

MANUFACTURER 

Page 42 

Page 5 

Summary of Contents for LS150

Page 1: ...LS150 MANUEL D INSTALLATION D ENTRETIEN ET D UTILISATION INSTALLATION MAINTENANCE AND USER MANUAL English page 32 SEP 18 2015 ...

Page 2: ... INSTRUCTIONS CONTENUES DANS CE MANUEL NE SONT PAS SUIVIES À LA LETTRE CECI PEUT CAUSER UNE EXPLOSION OU UN INCENDIE QUI POURRAIT ENTRAÎNER LA MORT OU DES LÉSIONS CORPORELLES ET OU DES DOMMAGES MATÉRIELS IMPORTANTS MISE EN GARDE UNE INSTALLATION DES AJUSTEMENTS DU SERVICE OU DE L ENTRETIEN INCORRECTS PEUVENT CAUSER UNE EXPLOSION OU UN INCENDIE QUI POURRAIT ENTRAÎNER LA MORT OU DES LÉSIONS CORPOREL...

Page 3: ...mbreuses années Ce manuel contient les directives et les mesures de sécurité nécessaires à l installation à la mise en service à l entretien et à l utilisation de ce type d appareil INFORMATIONS GÉNÉRALES Mise en garde Il est d une importance capitale de respecter les dégagements minimaux aux matériaux combustibles comme indiqué sur la plaque d homologation afin d éviter un incendie ou une explosi...

Page 4: ... C or more ELECTRICAL SUPPLY OF THE BOILER The electrical wiring to the boiler must conform to the Canadian Electrical Code and to the local codes these having precedence in certain municipalities In the case of the wood heating Bilovax LS150 provide an electrical circuit of 120Vac 1ph 60Hz protected by a breaker of the appropriate capacity In the case of the Dual Energy Bilovax LS150 provide an e...

Page 5: ...from the boiler by lightly pulling on the lever of the safety relief valve Purge all the air from the heating loop by pressing on the valve stem of the air purge remove cap If air is present wait until clear water is evacuated before releasing the lever of the safety relief valve or the air purge valve stem Check that the circulating pump and the combustion air damper are both fully functional SEC...

Page 6: ...e loading door of the Bilovax LS150 slowly and carefully to the first detent without using any force against the safety latch Pull on the smoke bypass damper lever to evacuate all the smoke and unburned gases from the combustion chamber After 30 seconds to a minute open the loading door fully past the second detent and put a full load of wood in the Bilovax LS150 on the embers Then firmly close th...

Page 7: ... also to help to increase the life of the system A system of filtration can also be recommended when there is a high rate of particles a temperature above 5 o C 40 o F must always be maintained in the room where the boiler is installed to protect it from freezing With a mixture of water and 54 propylene glycol or ethylene glycol it is possible to protect the boiler and the heating loop piping up t...

Page 8: ...constant supply temperature less the return temperature from the heating loop For example a boiler may have a supply temperature of 180 F and a return temperature of 160 F the T is then 20 F 11 C 180 F 160 F T or TEMPERATURE DROP THROUGH THE HEATING LOOP Type of system Boiler Supply Temperature Boiler Return Temperature T or Temperature Drop Through Boiler Baseboards 190 to 140 F 88 60 C 170 to 12...

Page 9: ...TU h ou 6 kW h Tous ces régulateurs et éléments de protection sont requis pour l opération sécuritaire de la chaudière Bilovax LS150 CLAPET ANTIRETOUR Si le système de chauffage utilise une seule pompe un clapet antiretour doit être installé pour empêcher la circulation par gravité et les pertes de chaleur inutiles durant les périodes sans demande de chauffage Aussi installer des clapets antiretou...

Page 10: ...use It is preferable that the piping not go through an unheated space on the other hand if this cannot be avoided it is most important to thermally insulate the piping and to install heating cables to eliminate any and all risks of freezing of the pipes Even where the piping of the heating loop goes through a heated space it is a good practice to insulate the pipes to minimize heat losses It is re...

Page 11: ...ion constante moins la température du retour de l eau de chauffage Par exemple une chaudière peut avoir une température d alimentation de 180 F Avec une température de retour de 160 F le T est donc de 20 F 11 C 180 F 160 F T ou BAISSE DE TEMPÉRATURE À TRAVERS LA BOUCLE DE CHAUFFAGE Type de système Température d alimentation Température de retour T ou Baisse de température Plinthes chauffantes 190 ...

Page 12: ...urité à deux étages d ouverture tirez sur le levier du clapet de dérivation pour évacuer toute la fumée et tous les gaz non brûlés après 30 secondes à une minute ouvrez toute grande la porte et mettez une pleine charge de bois dans le Bilovax sur les tisons et la braise et ensuite refermez le clapet de dérivation et la porte Le cycle normal de combustion devrait redémarrer dans un court délai Avec...

Page 13: ...r automatique on doit enlever le capuchon Si de l air sort attendez qu un peu d eau sorte avant de relâcher le levier de la soupape de surpression ou la tige du purgeur d air automatique Pourcentages typiques dans un mélange eau antigel propylène et glycol Dowfrost qui protégera du gel la chaudière et la tuyauterie de la boucle de chauffage aux températures mentionnées Température O C O F d antige...

Page 14: ...N OR WARNING Please understand the full meaning of the following words DANGER CAUTION or WARNING These words are associated with safety and it s symbols You will find them in the manual in the following manner DANGER The word DANGER indicates the gravest of dangers those that will result in loss of life or major injuries and or serious property damages CAUTION The word CAUTION indicates a danger w...

Page 15: ...t nettoyage de la chambre de combustion IMPORTANT Inspecter la chambre de combustion en vérifiant que les tuiles réfractaires sont en bon état et bien assujetties Si des tuiles réfractaires sont endommagées remplacez les par des tuiles neuves Pour ce faire enlevez le panneau en tôle avant de la chaudière la façade démontable de la chambre de combustion et remplacez les tuiles endommagées Pour comm...

Page 16: ...n pour le mode chauffage au bois et aussi pour le chauffage électrique où chaque élément possède aussi sa lampe témoin Avec l option biénergie et les interrupteurs de modes il est possible de chauffer seulement au bois de chauffer seulement avec les éléments électriques ou les deux modes ensemble Avec les deux modes en fonction cette option permet de ne pas manquer de chauffage lorsque le bois est...

Page 17: ...ses différents composants Surtout ne pas oublier que tous les composants du système peuvent affecter le fonctionnement sécuritaire de l appareil et que les techniciens doivent prendre connaissance des particularités de l appareil avant de procéder à son dépannage MISE EN GARDE Si le technicien désire utiliser un cavalier pour faire dérivation autour d un composant qu il veut isoler afin de faire u...

Page 18: ...E ACCORDING TO STANDARD CODE GAUGE C A SHUT OFF VALVE ELECTRIC CONTROL LINE ROOM TEMPERATURE CONTROLLER THERMOSTAT SEVERAL RELAY CONTACTS EXPANSION TANK NO 60 MINIMUM HEATING COIL AIR SEPARATOR COMPRISING AN AIR PURGE LEGEND TUYAUTERIE D ALIMENTATION D EAU CHAUDE TUYAUTERIE DE RETOUR D EAU FROIDE UNION DE BRIDE ROBINET À VANNE CLAPET DE RETENU DOUBLE ROBINET DE VIDANGE AVEC RACCORD POUR BOYAU ET B...

Page 19: ...ECTION TO A RADIANT FLOOR P2 Page 18 Page 29 Identification des borniers du panneau électrique Identification of electrical panel terminals IMPORTANT Les pompes P1 et P2 doivent être alimentés par l entrée électrique du bâtiment et protégées par un circuit d un maximum de 15 AMP NE JAMAIS RACCORDER P1 ET P2 DIRECTEMENT À LA CHAUDIÈRE The pumps P1 and P2 must be powered by the electrical input of t...

Page 20: ...SEBOARD 2 PLINTHE BASEBOARD 3 EXP P2 P1 Page 28 Page 19 240 VCA VAC 120 VCA VAC SCHEMA ÉLECTRIQUE CHAUDIÈRE LS150 bois électrique WIRING SCHEMATIC LS150 BOILER wood electric L1 L2 N L1 T1 M3 M4 EL 1 T3 L3 M3 M4 EL 2 L2 T2 M3 M4 EL3 T4 L4 M3 M4 EL 4 FUSIBLE FUSE 15 AMP AQUASTAT L6006A1145 INTERRUPTEUR ÉLECTRIQUE ELECTRIC SWITCH R HAUTE LIMITE HIGH LIMIT W B 200 ZONE DE DÉLESTAGE DIVERTING ZONE 120 ...

Page 21: ...the back of the boiler T T T Zone 1 Zone 2 S C EXP P2 P1 T 240 VCA VAC L1 SCHEMA ÉLECTRIQUE CHAUDIÈRE LS150 bois électrique WIRING SCHEMATIC LS150 BOILER wood electric N L1 120 VCA VAC L2 C1 S1 C1 S2 C1 S1 C1 L1 T1 M3 M4 EL 1 T3 L3 M3 M4 EL 2 L2 T2 M3 M4 EL3 T4 L4 ZONE DE DÉLESTAGE DIVERTING ZONE AQUASTAT L6006A1145 INTERRUPTEUR ÉLECTRIQUE ELECTRIC SWITCH A1 C1 A2 FUSIBLE FUSE 15 AMP B R W 200 120...

Page 22: ...EMENT AVEC CONTRÔLE DE BASSE TEMPÉRATURE RACCORDÉ À LA CHAUDIÈRE THE SETTING OF THE OTHER HEATING SYSTEM MUST BE AT A MINIMUM OF 150 f TO AVOID TURNOFF OF THE SUPPLY PUMPS P2 connected to the aquastat at the back of the boiler P1 CONTINUING CIRCULATION FOR MIXING OF WATER P2 CONNECTION WITH LOW TEMPERATURE CONTROL CONNECTED TO BOILER ÉCHELLE AUCUNE SCALE NONE RÈGLAGE MINIMUM À 150 F MINIMUM SETTIN...

Page 23: ...anne résultant d une installation réparation entretien ou usage non conforme à la réglementation en vigueur ou 3 Vice ou panne résultant d une installation réparation entretien ou usage négligent ou résultant d un bris causé par le propriétaire ou entretien incorrect mauvais usage accident ou modification ou 4 Vice ou panne causé par le gel les inondations et les intempéries ou 5 Installation sans...

Page 24: ...y or 12 That the serial number has been altered or erased from the nameplate by persons unknown Limitations L S Bilodeau inc will not be liable for incidental or consequential damages loss or inconvenience of any sort directly or indirectly pursuant to a failure or breakdown of the Bilovax LS150 boiler All implied warranties of merchantability and fitness for a particular use or purpose are hereby...

Reviews: