IM-A-1048H
55
8. SPECIFICATIONS
(1) Number of channel
1
(2) Applicable sensor
Strain gage transducers (4-wire system)
(4) Bridge excitation
10 VDC, 2 VDC, selectable
(5) Measurement range
±3.2 mV/V
(input range including zero adjustment range)
(6) Zero adjustment range
Within measurement range
(not retained when power supply interrupted)
(7) Nonlinearity
Within ± (0.02 %FS 1 digit)
RTI
/°C
Sensitivity: Within ±0.01 %/°C
(9) Sampling speed
4000 times/s
(10) A/D resolution
24 bits
(11) Calibration
Actual load calibration, Sensitivity registering calibration, and
Numeric value registering calibration
(12) Smoothing function
Filter: 10, 30, 100, and flat(300 Hz)
Attenuation characteristics:-12 dB/oct.
Moving average:
None, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, and 2048 times
Minimum scale:
1, 2, 5, 10, 20, 50, 100, 200, 500, and 1000 counts
(13) Automatic ZERO compensation function
Zero tracking (Auto digital Zero within the setting range)
Zero near zero (Automatic Zero display)
(14) Additional function
Setting range: ±99999
(15) Original value display function
±3.2000 mV/V
Accuracy: Within ±0.1 %FS