IM-A-1048H
44
FUNCTION
SELECTING
MODE
Key operation and WGA-680A movement
in SETTING mode
Functional description,
supplements
F-12
Initialize
<To enable the key code>
The "00000" is displayed.
Set the "00628" or
"11111"and press the SET key.
The pre-set value returns to the
factory default setting.
After the settings, the key code is
enabled. To return the pre-set value to the factory default
setting next time, you are required to enter the key code.
To disable the key code, execute the "F-12".
<To disable the key code>
The "00000" is displayed.
Press the SET key.
The pre-set value returns to the factory default setting.
After the settings, the key code is disabled. You are able
to return the pre-set value to the factory default setting
without entering the key code.
The pre-set value returns to the factory default setting.
Sensitivity registering calibration(F-03), bridge
excitation(F-13) and numeric value registering
calibration(F-19) are not initialized.
A function that returns the
pre-set values to the
factory default.
The "00628" and "11111"
are key codes. The key
codes prevents the
calibration values from
carelessly changing due to
malfunctions.
F-13
BV selection
The pre-set value is displayed.
0: 10 V
1: 2 V (Initial value)
Set the value and press the SET key.
A function that selects and
changes the bridge
excitation voltage.
For details, see "4-2. TO
SELECT BRIDGE
EXCITATION
VOLTAGE".
F-14
TEDS reading
item
For details, see separate volume of
"INSTRUCTION MANUAL (FOR BCD/RS-232C/
RS-485/TEDS OPTIONS) ".
BCD/TEDS model,
RS-232C/TEDS model
and RS-485/TEDS model
only.
F-16
RS
communication
Settings
For details, see separate volume of
"INSTRUCTION MANUAL (FOR BCD/RS-232C/
RS-485/TEDS OPTIONS)".
RS-232C/TEDS model
and RS-485/TEDS model
only.
F-17
Device ID
For details, see separate volume of
"INSTRUCTION MANUAL (FOR BCD/RS-232C/
RS-485/TEDS OPTIONS) ".
RS-485/TEDS model only.
F-18
CC-Link
For details, see separate volume of
"INSTRUCTION MANUAL (FOR CC-LINK OPTION)".
CC-Link model only.