4-12-2. Error codes
Error
Contents
Countermeasures
OFL1
The measured value is exceeding the input
range to the minus side.
Decrease the input signal.
Use the input signal within ±3.2 mV/V.
OFL2
The measured value is exceeding the input
range to the plus side.
OFL3
The indicated value is below -99999.
Decrease the input signal or reset the sensitivity
registering value.
OFL4
The indicated value is above +99999.
E-00
The sensitivity registering value is exceeding
the specified range.
Use the sensitivity registering value 10000 or less
per 0.1 mV/V.
E-01
RAM Failure
Failure
Contact KYOWA or our representatives for
repair.
E-02
Flash memory Failure
E-03
TEDS Failure
Check that the TEDS transducer is correctly