2NP
1-2-29
16. Pass the key counter electrical wires
through the edging.
17. Connect the connector of the key
counter electrical wires to the connector
of the option PWB.
18. Fit the scanner rear cover using two
screws.
19. Fit the right upper cover.
Note: Pass the connector of the key
counter wire through the aperture (right
side) in the right upper cover.
Note: Be careful not to put a key coun-
ter electric wire with the upper right
cover.
20. Fit the scanner right cover using two
screws.
Figure 1-2-36
21. Fit the tray stay to the scanner right
cover using two screws.
Figure 1-2-37
Edging
Connector
Option PWB
Key counter
electrical wires
Key counter
electrical wires
Aperture
Scanner right cover
M4 x 10 screw
M4 x 10 screw
Tray stay
Key counter
electrical wires
Summary of Contents for TASKalfa 2551ci
Page 1: ...SERVICE MANUAL Published in September 2016 842NP11A 2NPSM06A Rev A TASKalfa 2551ci ...
Page 10: ...This page is intentionally left blank ...
Page 97: ...2NP 1 1 2 74 This page is intentionally left blank ...
Page 259: ...2NP 1 3 162 U486 Details on the modes Figure 1 3 47 Item No Description ...
Page 473: ...2NP 1 5 62 This page is intentionally left blank ...
Page 497: ...2NP 2 1 22 This page is intentionally left blank ...
Page 555: ...2NP 2 3 48 This page is intentionally left blank ...
Page 584: ...Installation Guide DP 770 B Document processor DP 772 Document processor Installation Guide ...
Page 620: ...DP 773 Document processor Installation Guide ...
Page 646: ...PF 791 500 x 2 Paper feeder Installation Guide ...
Page 654: ...PF 810 3000 sheets deck Installation Guide ...
Page 667: ...DF 770 D Document finisher Installation Guide ...
Page 685: ...AK 740 Bridge unit Installation Guide ...
Page 687: ...PH 7A C D Punch unit Installation Guide ...
Page 708: ...DT 730 B Document tray Installation Guide ...
Page 710: ...5 2013 5 302LC56750 01 H F G D D 6 4 3 7 E C D D M4 8 M4 8 M4 8 M4 8 ...
Page 711: ...FAX System W B Installation Guide ...