2NP
1-4-27
2310
Fuser motor startup error
Fuser motor is not stabilized
within 3 s since the motor is
activated.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Fuser motor and engine PWB (YC17)
Defective drive
transmission sys-
tem.
Check if the rollers and gears rotate
smoothly. If not, grease the bushings and
gears. Check for broken gears and replace if
any.
Defective motor.
Replace the fuser motor.
Defective PWB.
1. Check the engine software and upgrade
to the latest, if necessary.
2. Replace the engine PWB and check for
correct operation (see page 1-5-39).
2500
Conveying motor 2 steady-
state error
The rated speed signal
detected the stability OFF
continuously for 1 s after the
conveying motor 2 stabilizes.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Conveying motor 2 and video PWB (YC28)
Defective drive
transmission sys-
tem.
Check if the rollers and gears rotate
smoothly. If not, grease the bushings and
gears. Check for broken gears and replace if
any.
Defective motor.
Replace the Conveying motor 2.
Defective PWB.
1. Check the engine software and upgrade
to the latest, if necessary.
2. Replace the video PWB and check for
correct operation (see page 1-5-54).
2510
Conveying motor 2 startup
error
Conveying motor 2 is not sta-
bilized within 2 s since the
motor is activated.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Conveying motor 2 and engine PWB (YC28)
Defective drive
transmission sys-
tem.
Check if the rollers and gears rotate
smoothly. If not, grease the bushings and
gears. Check for broken gears and replace if
any.
Defective motor.
Replace the conveying motor 2.
Defective PWB.
1. Check the engine software and upgrade
to the latest, if necessary.
2. Replace the engine PWB and check for
correct operation (see page 1-5-39).
Code
Contents
Causes
Check procedures/
corrective measures
Summary of Contents for TASKalfa 2551ci
Page 1: ...SERVICE MANUAL Published in September 2016 842NP11A 2NPSM06A Rev A TASKalfa 2551ci ...
Page 10: ...This page is intentionally left blank ...
Page 97: ...2NP 1 1 2 74 This page is intentionally left blank ...
Page 259: ...2NP 1 3 162 U486 Details on the modes Figure 1 3 47 Item No Description ...
Page 473: ...2NP 1 5 62 This page is intentionally left blank ...
Page 497: ...2NP 2 1 22 This page is intentionally left blank ...
Page 555: ...2NP 2 3 48 This page is intentionally left blank ...
Page 584: ...Installation Guide DP 770 B Document processor DP 772 Document processor Installation Guide ...
Page 620: ...DP 773 Document processor Installation Guide ...
Page 646: ...PF 791 500 x 2 Paper feeder Installation Guide ...
Page 654: ...PF 810 3000 sheets deck Installation Guide ...
Page 667: ...DF 770 D Document finisher Installation Guide ...
Page 685: ...AK 740 Bridge unit Installation Guide ...
Page 687: ...PH 7A C D Punch unit Installation Guide ...
Page 708: ...DT 730 B Document tray Installation Guide ...
Page 710: ...5 2013 5 302LC56750 01 H F G D D 6 4 3 7 E C D D M4 8 M4 8 M4 8 M4 8 ...
Page 711: ...FAX System W B Installation Guide ...