9.Electrical Systems
XCITING S 400
9-20
Charging System
To replace the stator/charging coil see the A.C. Generator and Starter clutch
topic.
Charging Voltage Inspection
Remove the battery cover. See the Battery topic for more information.
Note: The battery should be fully charged prior to making charging system
checks.
Start the engine and warm it up to the operating temperature; stop the engine.
Connect the multimeter between the positive (+) and negative (-) terminals of the
battery. To prevent short, make absolutely certain which are the positive (+) and
negative (-) terminals or cable.
Turn the ignition switch on and turned to the high beam position, restart the
engine. Measure the voltage on the multimeter when the engine runs at 5000
rpm.
Battery charging voltage@ 5000 rpm
14 ~ 15V
Summary of Contents for ADG5
Page 12: ...1 Quick Reference XCITING S 400 1 12 Torque Engine Specifications...
Page 13: ...1 Quick Reference XCITING S 400 1 13 Torque Frame Specifications...
Page 16: ...1 Quick Reference XCITING S 400 1 16 General Troubleshooting...
Page 17: ...1 Quick Reference XCITING S 400 1 17...
Page 18: ...1 Quick Reference XCITING S 400 1 18...
Page 19: ...1 Quick Reference XCITING S 400 1 19...
Page 20: ...1 Quick Reference XCITING S 400 1 20 VIN and Engine Number Location...
Page 23: ...2 Periodic Maintenance XCITING S 400 9 3...
Page 114: ...3 Engine Valves XCITING 400i Remove the spring retainer Remove the valve springs 3 36...
Page 329: ...9 Electrical Systems XCITING S 400 9 29 Check the circuit with the wire...
Page 340: ...10 Brake System XCITING S 400 Diagram 10 3...
Page 362: ...10 Brake System XCITING S 400 Pre diagnosis Inspection Chart 1 10 25...
Page 363: ...10 Brake System XCITING S 400 Pre diagnosis Inspection Chart 2 10 26...