Lock Section Calibrations
See “How to Enter Calibration Data” on page 2-42
enter calibration data.
Lock Locations:
Set the lock locations
for 3 standard door
lengths.
To calibrate, run a
known good lock cut at
a standard location on a
Right Hand or Left
Hand door.
Once the lock cut is
completed, check the
distance from the top of
the door to the center of
the lock.
Note the measurement
value and compare to
specification.
Re run the calibration
routine until correct.
Face Bore Extend
Timers
:
This machine is
designed to bore a lock
with a three stage bit.
This menu allows you
to set the bore times of
each stage. (Shallow,
Mid and Deep)
Face Plate Timers
Vertical:
The amount of time, in seconds, to
give the vertical movement of the lock plate
when in “Fast Plate” or “Slow Plate” mode.
Horizontal:
The amount of time, in seconds, to
give the horizontal movement of the lock plate
when in “Fast Plate” or “Slow Plate” mode.
Single Step Disable/Enable Button:
Disable
the
Single Step
button to use the three stages.
Enable
the
Single Step
button to by pass the
three stages and perform the bore with one sin-
gle cut.
Lock Location
Measurements
Note
: Before adjusting the
Slow Lock Plate Timing,
make sure the Fast Plate
Routine is set properly
adjusted.
Setup Screen
2-46
990-HQ Operation Manual