Safety Controls
2-26
990-HQ Operation Manual
Safety Controls
Emergency Shutdown and Recovery
Depending on the model of machine, there are emergency shutdown (E-
Stop) switches located at key points around the machine.
The E-Stop switches are to be used when the machine is out of control or is
about to damage personnel or equipment.
When an E-Stop switch is activated, high voltage power is cut to the
machine. The motors will stop but power to the PLC and the Operator Sta-
tion Screen will remain on.
Note:
The machine responds in the same way if you press the STOP button on the
operator's station.
To Resume Normal Operation after an E-Stop
If an E-Stop is activated, use the following procedure to recover, after the cause of the emergency
stop is resolved:
1.
De-activate the E-Stop switch by pulling it out.
2.
Push the
START MACHINE
button on the operator's station.
3.
Press the
Reset Light Curtain Buttons
on the Feeder.
4.
Re-Home the machine and continue running the process.
Air Brake on 990-HQ Eight Shooter
The 990-HQ has air brakes on the Eight Shooter assemblies. The brakes will lock the shooter in
place avoiding a crash to the head. The brakes are controlled by a lack of air pressure and will
lock when the air pressure drops below a reference level.
Brakes are located on
each side of the eight
shooter assemblies
Manifold
Air Sensor:
Approximately Minimum 75
psi threshold to activate the
brake.