Key functions
ENT
Reversal of the sense of rotation independent of the control signal on the
terminals Clockwise S2IND or Anticlockwise S3IND.
ESC
Cancel function and return to the menu structure.
FUN
Switch from internal set point
int
or motor potentiometer function
Pot
to
JOG frequency; the drive starts.
Release the key to switch to the sub-function and stop the drive.
RUN
Start drive; alternative to control signal S2IND or S3IND.
STOP
Stop drive; alternative to control signal S2IND or S3IND.
Attention!
If you press the ENT key, the
sense of rotation is changed
inde-
pendent of the signal on the terminals Clockwise S2IND or Anticlock-
wise S3IND.
If the
minimum frequency
418
has been set to 0.00 Hz, the
sense of
rotation
of the motor changes as soon as the sign of the reference
frequency value changes.