KFU 2-/4-
116
11.2 Stopping
Behavior
The stopping behavior of the three-phase machine can be defined via parameter
Operation mode
630
. Via the logic signals or digital inputs for the parameters
Start
clockwise
68
and
Start anticlockwise
69
, stopping is activated. Assign digital inputs or
logic signals to these parameters. Dependent on the setting of
Configuration
30
the
parameters are preset to digital inputs. By combining the digital input signals or logic
signals the stopping behavior can be selected from the following table.
Stopping Behavior
Start clockwise = 0 and Start anticlockwise = 0
Operation mode
630
Stopping be
ha
vio
r 0
Stopping be
ha
vio
r 1
Stopping be
ha
vio
r 2
Stopping be
ha
vio
r 3
Stopping be
ha
vio
r 4
Stopping be
ha
vio
r 5
Stopping be
ha
vio
r 6
Stopping be
ha
vio
r 7
Stopping behavior 0
(Free stopping)
0 1 2 3 4 5 6 7
Stopping behavior 1
(Stop
and Switch off)
10 11 12 13 14 15 16 17
Stopping behavior 2
(Stop
and Hold)
20 21 22 23 24 25 26 27
Stopping behavior 3
(Stop
and DC brakes)
30 31 32 33 34 35 36 37
Stopping behavior 4
(Emergency Stop
and Switch off)
40 41 42 43 44 45 46 47
Stopping behavior 5
(Emergency Stop
and Hold)
50 51 52 53 54 55 56 57
Stopping behavior 6
(Emergency Stop
and Brake)
60 61 62 63 64 65 66 67
Start clo
ckw
ise = 1 and S
tart a
n
ticloc
kwise = 1
Stopping behavior 7
(DC brakes)
70 71 72 73 74 75 76 77
Operation mode
630
of the stopping behavior is to be parameterized according to the
matrix. The selection of the operation modes can vary according to the control
method and the available control inputs.
Example:
The machine is to stop according to stopping behavior 2 if the digital logic
signals
Start clockwise
68
= 0 and
Start anticlockwise
69
= 0.
Additionally, the machine is to stop according to stopping behavior 1 if the digital logic
signals
Start clockwise
68
= 1 and
Start anticlockwise
69
= 1.
To achieve this, the parameter
Operation mode
630
must be set to 12.
By selecting the stopping behavior you also select the control of a mechanical brake if
operation mode „41- Brake release“ is used for one digital output for controlling the