KFU 2-/4-
236
19.2 Error
Environment
The parameters of the error environment help troubleshooting both in the settings of
the frequency inverter and also in the complete application. The error environment
documents the operational behavior of the frequency inverter at the time of the last
four faults.
Error Environment
No.
Description
Function
330
DC –Link Voltage
Direct voltage in the DC link.
331
Output voltage
Calculated output voltage (motor voltage) of the
frequency inverter.
332
Stator frequency
The output voltage (motor voltage) of the fre-
quency inverter.
333
Frequency Speed Sensor 1
Calculated from the data on speed sensor 1, the
No. of pole pairs
373
and the speed sensor signal.
335
Phase current Ia
Measured current in motor phase U.
336
Phase current Ib
Measured current in motor phase V.
337
Phase current Ic
Measured current in motor phase W.
338
R.m.s current
Calculated effective output current (motor current)
of the frequency inverter.
339
Isd / reactive current
Current component forming the magnetic flux or
the calculated reactive current.
340
Isq / active current
Current component forming the torque or the cal-
culated active current.
341
Rotor magnetizing current Magnetizing current relative to the rated motor
parameters and the operating point.
342
Torque
Torque calculated from the voltage, the current
and the control variables.
343
Analog input MFI1A
Input signal on multifunctional input 1 in
Opera-
tion mode
452
- analog input.
346
Analog output MFO1A
Output signal on multifunctional input 1 in
Op-
eration mode
550
– analog.
349
Repetition frequency out-
put
Signal at repetition frequency output according to
Operation mode
550
– repetition frequency.
350
Status of digital inputs
Decimally coded status of the six digital inputs and
of multifunctional input 1 in
Operation mode
452
-
digital input.
351
Status of digital outputs
Decimally coded status of the two digital outputs
and of multifunctional output 1 in
Operation mode
550
– digital.
352
Time since release
The time of the error in hours (h), minutes (m)
and seconds (s) after the release signal:
hhhhh:mm:ss .
sec
/
10
sec
/
100
sec
/
1000
.
353
Heat sink temperature
Measured heat sink temperature.
354
Inside temperature
Measured inside temperature.
355
Controller Status
The reference value signal is limited by the control-
ler coded in the controller status.
356
Warning Status
The warning messages coded in warning status.
357
Int. value 1
Software service parameter.
358
Int. value 2
Software service parameter.
359
Long value 1
Software service parameter.
360
Long value 2
Software service parameter.