KFU 2-/4-
241
Example:
The following warning status is displayed:
A008D Ixt IxtLt Tc PTC
The warning status results from the hexadecimal sum of the warning
codes (0001+0004+0008+0080 = 008D).
The short-term overload (1 s), warning limit heat sink temperature and
warning limit motor temperature warnings are present.
Output signals
The output of a warning message is signaled.
169 - General Warning
1)
11 - Warning, General
2)
The output of a warning message in
Warnings
269
is
signaled.
1)
For linking with inverter functions
2)
For digital output
Meaning of code displayed by parameter
Application Warning Status
367
:
Code
Warning Status
A 00 00 NO WARNING No warning message present.
A
00
01
BELT
Warning V-belt by
Operation mode
581
.
A
00
02
SW-LIM
CW
The positive SW limit switch was reached (parameter
Positive SW limit switch
1145
).
A
00
04
SW-LIM
CCW
The negative SW limit switch was reached (parameter
Negative SW limit switch
1146
).
A
00
08
HW-LIM
CW
The positive HW limit switch was reached.
A
00
10
HW-LIM
CCW
The negative HW limit switch was reached.
A
00
20
CONT
The contouring error monitoring range adjusted with
parameter
Warning Threshold
1105
was left.
Output signals
The output of an application warning message is signaled.
216 - Application Warning
1)
26 - Warning, Application
2)
The output of a warning message in
Application
Warnings
273
is signaled.
1)
For linking with inverter functions
2)
For digital output