KFU 2-/4-
233
19 Error
Protocol
The various control methods and the hardware of the frequency inverter include func-
tions which continuously monitor the application. The operational and error diagnosis
is facilitated by the information stored in the error protocol.
19.1 Error
List
The last 16 fault messages are stored in chronological order and the
No. of errors
362
shows the number of errors which have occurred since initial commissioning of
the frequency inverter. In the VAL menu branch of the control unit, the error code
FXXXX is displayed. The meaning of the error key is described in the following chap-
ter "Error Messages". Via the PC program, the number of operation hours (h), opera-
tion minutes (m) and the fault message can additionally be read out. The current op-
erating hours can be read off via the
Operation hours counter
245
. The fault report
can be acknowledged via the keys of the operating unit and according to the assign-
ment
Error acknowledgment
103
.
Error List
No.
Description
Function
310
Last error
hhhhh:mm ; FXXXX fault message.
311
Last error but one
hhhhh:mm ; FXXXX fault message.
312 to 325
Error 3 to error 16.
362
No. of errors
Number of errors occurred after the initial com-
missioning of the frequency inverter.
The error and warning behavior of the frequency inverter can be set in various ways.
The automatic error acknowledgment enables acknowledgment of the faults Overcur-
rent F0500, Overcurrent F0507 and Overvoltage F0700 without intervention by an
overriding control system or the user. The
No. of self acknowledged errors
363
shows
the total number of automatic error acknowledgments.
Error List
No.
Description
Function
363
No. of self acknowledged
errors
Total number of automatic error acknowledg-
ment with synchronization.
19.1.1 Error
Messages
The error code stored following a fault comprises the error group FXX and the fol-
lowing code number XX.
Error Messages
Code
Meaning
F00
00
No fault has occurred.
Overload
F01
00
Frequency inverter overloaded.
02
Frequency inverter overloaded (60 s), check load behavior.
F01
03
Short-term overload (1 s), check motor and application parameters.
Table "Fault Messages" continued on next page.