![Küenle KFU 2 Series Manual Download Page 233](http://html.mh-extra.com/html/kuenle/kfu-2-series/kfu-2-series_manual_2009350233.webp)
KFU 2-/4-
232
18.4.2 Volume Flow and Pressure
The parameterization of the factors
Nominal Volumetric Flow
397
and
Nominal Pres-
sure
398
is necessary if the matching actual values
Volumetric Flow
285
and
Pres-
sure
286
are used to monitor the drive. The conversion is done using the electrical
control parameters.
Volume flow
285
and
Pressure
286
are referred to the
Effective
current
214
in the case of the sensorless control methods. In the case of the field-
oriented control methods, they are referred to the torque-forming current component
Isq
216
.
Volume Flow and Pressure
No.
Description
Function
285
Volumetric flow
Calculated volume flow with the unit m
3
/h.
286
Pressure
Pressure calculated according to the character-
istic with the unit kPa.