KFU 2-/4-
165
Create Warning Mask
536
Function
35
-
Controller I abs
The output current is limited.
36 -
Controller
Torque Limitation
The output power or the torque is limited by the
speed controller.
37 -
Controller
Torque Control
Switch-over of field-orientated control between
speed and torque-controlled.
38 -
Ramp Stop
The
Operation mode
620
selected in starting be-
havior limits the output current.
39 -
Contr. Intel. Curr. Lim.
LT-Ixt
Overload limit of the long-term Ixt (60s) reached,
intelligent current limits active.
40 -
Contr. Intel. Curr. Lim.
ST-Ixt
Overload limit of the short-term Ixt (1s) reached,
intelligent current limits active.
41 -
Contr. Intel. Curr. Lim.
Tc
Max. heat sink temperature T
K
reached,
Operation
Mode
573
for the intelligent current limits active.
42 -
Contr. Intel. Curr. Lim.
Motor Temp.
Max. motor temperature T
PTC
reached,
Operation
Mode
573
for the intelligent current limits active.
43 -
Controller
Freq. Limitation
The reference frequency has reached the
Maximum
Frequency
419
. The frequency limitation is active.
101 to 143
Removal or deactivation of the operation mode with-
in the warning mask.
The selected warning mask can be read out via the parameter
Actual Warning Mask
537
. The above operation modes of parameter
Create Warning Mask
536
are en-
coded in the
Actual Warning Mask
537
. The code results from hexadecimal addition
of the individual operation modes and the matching abbreviation.
Warning code
Create Warning Mask
536
A FFFF FFFF
-
1 - Activate everything
A 0000 FFFF
-
2 - Activate all Warnings
A FFFF 0000
-
3 - Activate all Controller States
A 0000 0001
Ixt
10 - Warning Ixt
A 0000 0002
IxtSt
11 - Warning Short-Term Ixt
A 0000 0004
IxtLt
12 - Warning Long-Term Ixt
A 0000 0008
Tc
13 - Warning Heat Sink Temperature
A 0000 0010
Ti
14 - Warning Inside Temperature
A 0000 0020
Lim
15 - Warning Limit
A 0000 0040
INIT
16 - Warning Init
A 0000 0080
MTemp
17 - Warning Motor Temperature
A 0000 0100
Mains
18 - Warning Mains Failure
A 0000 0200
PMS
19 - Warning Motor Protective Switch
A 0000 0400
Flim
20 - Warning Fmax
A 0000 0800
A1
21 - Warning Analog Input MFI1A
A 0000 1000
A2
22 - Warning Analog Input MFI2A
A 0000 2000
Sysbus
23 - Warning Systembus
A
0000
4000
UDC
24
- Warning
Udc
A 0000 8000
WARN2
25 - Warning application
A 0001 0000
UDdyn
30 - Controller Udc Dynamic Operation
A 0002 0000
UDstop
31 - Controller Shutdown
A 0004 0000
UDctr
32 - Controller Mains Failure
A 0008 0000
UDlim
33 - Controller Udc Limitation
A 0010 0000
Boost
34 - Controller Voltage Pre-Control
A 0020 0000
Ilim
35 - Controller I abs
A 0040 0000
Tlim
36 - Controller Torque Limitation