Symbol/Icon
Parameter name
Value range (factory default)
Type of storage tank priority
1 to 5 (3)
Charging time for low priority storage tank
only for priority type 3
0 to 120 min (150 min)
Minimum storage temperature for storage
tank charging
only for priority type 2
5 to 90 °C (30 °C)
Maximum collector temperature
(turn-off condition)
90 to 160 °C (130 °C)
Maximum collector temperature
(turn-on condition)
90 to 160 °C (110 °C)