KT-Elektronik
SOL3-3
3 Manual operating mode
The manual operating mode allows the configuration of all outputs
(chapter 11).
Manual operating mode is set with the turn switch for the requested circuit:
Procedure:
Move rotary switch to position “Manual operating mode”.
Select menu item in compliance with the system variant:
POS2 : Position presetting for analogue output
UP1:
Operate the relay for heating circuit pump UP1
ZP:
Operate the relay of the circulation pump
CP1:
Operate the relay of the collector pump CP1
CP2:
Operate the relay of the collector pump CP2
CU:
Operate the relay of the collector switching valve CUV
SP1:
Operate the relay of the storage tank pump SP1
SP2:
Operate the relay of the storage tank pump SP2
NH:
Operate the relay for auxiliary heating NH
SU:
Operate the relay for the storage tank switching pump SUV
CTP:
Operate the relay for the collector heat exchanger pump CTP
TdS:
Operate the relay for the temperature difference switch TdS
Confirm selection. Display flashes.
Change the position, switching state of the pump and other units.
Confirm editing.
The changed values remain as long as the manual operating mode stays
active.
Move the rotary switch back to the "Information level" position
.
The manual operating mode of the affected control circuit can be
deactivated by selecting any other operating mode.
EB_37383_SOL3-3_EN002
25
Note:
Just by moving the rotary switch to the position “manual operating mode”, the
outputs of the controller are not affected. Only the specific change of position
respectively switching status will influence them.
In manual operating mode the antifreeze function cannot be guaranteed (Chapter 7.2).
Summary of Contents for SOL3-3
Page 1: ...Solar controller SOL3 3 Installation and operating manual Firmware version 1 07 April 2011...
Page 66: ...Installation and operating manual KT Elektronik Figure 12 Mounting 66 EB_37383_SOL3 3_EN002...
Page 86: ...Installation and operating manual KT Elektronik 86 EB_37383_SOL3 3_EN002...