KT-Elektronik
SOL3-3
programmed minimum rotation speed a signal for 0% (corresponding to 0 V output) is
sent.
The calculation is based on a PID algorithm, whose parameters can be customized.
Function
FS
Description
Rotation speed mode
Rotation speed set-point
Minimum rotation speed
Maximum rotation speed
PID control parameters
1
10
0%
100%
2.0
120 s
0 s
CO3 -> F04 Mode of rotation speed control / 1...2
Set
-point for rotation speed control / 1...100 °C
respectively K (Differential or absolute value)
Minimum rotation speed / 0 ... 50%
Maximum rotation speed / 50 ... 100%
KP (boost) / 0.1 to 50.0
TN (reset time) / 1 to 999 s
TV (retention time) / Do not change value!
5.7 Collector overheating protection
If the collector temperature exceed this maximum value (default factory setting is 130°C),
it is assumed that steam is already in the system, and therefore no circulation takes
place any more. The collector pump is turned off in this case until the temperature
dropped to a lower value (default factory setting is 110°C).
Setting
FS
Value range Description
Collector-Max A
PA3
130 °C 90 ... 160 °C Maximum collector temperature
(turn-off condition)
Collector-Max E
PA3
110 °C
90 ... 160 °C Maximum collector temperature
(turn-on condition)
EB_37383_SOL3-3_EN002
43
Summary of Contents for SOL3-3
Page 1: ...Solar controller SOL3 3 Installation and operating manual Firmware version 1 07 April 2011...
Page 66: ...Installation and operating manual KT Elektronik Figure 12 Mounting 66 EB_37383_SOL3 3_EN002...
Page 86: ...Installation and operating manual KT Elektronik 86 EB_37383_SOL3 3_EN002...
Page 87: ...KT Elektronik SOL3 3 EB_37383_SOL3 3_EN002 87...