12 Appendix
12.1 Function block lists
CO3: Solar circuit
F
Function
FS
Function block parameter description/value range (factory default
setting)
01
Forced pump
operation
0
CO3 F01 = 1 - Regular forced pump operation active
see section 5.10
02
Collector
antifreeze
0
CO3 F02 = 1 - Antifreeze active
see section 5.11
03
Start up function
(tube collector
function)
0
CO3 F03 = 1 - Start-up function active
see section 5.9
04
Rotation speed
control
CO3 F04 = 1 Rotation speed control active
see section5.6
05
Solar heat meter
0
CO3 F05 = 1 - Collector performance heat meter
see section 5.5
Function block parameter:
Heat capacity at 25°C, Heat capacity at 100°C
06
Heat meter-
impulse source
0
see section 5.5
CO3 F06 = 1 - Volume flow rate sensor active
Function block parameter: Impulse value
CO3 F06 = 0 - Volume flow rate replacement value active
Function block parameter: Volume flow rate replacement value
07
CVF
CO3 F07 = 1 - Collector flow sensor active
see section 5.3
08
CRF
CO3 F08 = 1 - Collector return flow sensor active
see section 5.3
09
CVF for CTP
0
CO3 F09 = 1 -Collector flow sensor CVF for exchanger pump
CTP active
see section 5.13
10
Temperature dif-
ference controller
0
10K
2
7
CO3 F10 = 1 Temperatur difference controller active
Function block parameter
Temperatur difference set point / -30 bis 160°C
Reference input / Terminal number 1...9
Controlled input / Terminal number 1...9
F Function block number, FS Factory default setting
EB_37383_SOL3-3_EN002
71
Summary of Contents for SOL3-3
Page 1: ...Solar controller SOL3 3 Installation and operating manual Firmware version 1 07 April 2011...
Page 66: ...Installation and operating manual KT Elektronik Figure 12 Mounting 66 EB_37383_SOL3 3_EN002...
Page 86: ...Installation and operating manual KT Elektronik 86 EB_37383_SOL3 3_EN002...
Page 87: ...KT Elektronik SOL3 3 EB_37383_SOL3 3_EN002 87...