2.2 Activate and deactivate functions
Each function can be activated within its related function block. The sequence of
numbers shown at the head of the display (0 to 24) represent the function block
numbers. When accessing the configuration level, a black square is displayed right hand
below active function block numbers. The function blocks are described in chapter 12.1.
The functions are grouped by topic:
CO3: Solar circuit
CO4: Domestic water circuit/auxiliary heating
CO5: System wide
CO6: Modbus-Communication
Procedure:
Switch to configuration and settings level.
Display shows 0 0 0 0
Enter a valid access code.
Confirm code.
Display: PA3
Select configuration level.
Access configuration level.
Select function block.
Activated function blocks are marked with "- 1".
Deactivated function blocks are marked with “- 0”.
Switch to edit mode.
F__ flashes
Activate function block.
Display: F__ - 1
An active function block can be identified by a black square that is
displayed right hand below the function block number at the head of the
display.