Installation and operating manual
KT-Elektronik
12.2 Parameter list
PA3: Solar circuit parameter level
Symbol/Icon
Parameter name
Value range (factory default)
Minimum running time for collector pump
0 to 1800 s (60s)
Minimum idle time for collector pump
0 to 1800 s (1800s)
Maximum storage tank temperature -
Turn-off condition
20 to 160 °C (60 °C)
(parameter for second storage is
additionally indicated by a '2')
Maximum storage tank temperature -
Turn-on condition
20 to 160 °C (58 °C)
(parameter for second storage is
additionally indicated by a '2')