5.3.1.6 Installing the pump set
NOTE
Make sure the pump set with the pre-assembled claw can easily be slipped over the
mounting bracket, threaded onto the guide rails and lowered down. If required, alter the
position of the crane during installation.
1. Guide the pump set over the suspension bracket/mounting bracket, thread it
onto the guide wires/rails and slowly lower it down.
The pump set attaches itself to duckfoot bend 72-1.
2. Attach lifting chain/rope to hook 59-18 at the mounting bracket.
5.3.2 Transportable wet installation
Installing the pump foot plate or pump stool
Before installing the pump, fit the pump foot plate or pump stool.
Tighten the screws as specified, see table “Tightening torques”. (
Attaching the lifting chain/rope
1. Attach the lifting chain or rope to the lug/eyebolt on the side of the discharge
nozzle (see illustration and table "Types of attachment").
Connecting the piping
The DIN connection is suitable for connecting rigid or flexible pipes.
Fig. 16: Types of connection
5.4
Electrical connection
5.4.1 Information for planning the control system
For the electrical connection of the pump set observe the wiring diagrams contained
in the Annex. (
The pump set is supplied with power cables; it is wired for DOL starting. Star-delta
starting is also possible.
NOTE
When laying a cable between the control system and the pump set's connection point,
make sure that the number of cores is sufficient for the sensors. A minimum cross-
section of 1.5 mm² is required.
Fig. 15: Attaching the