Attaching the lifting chain/rope
Attaching the lifting
chain/rope - stationary
wet installation
Stationary wet installation
1. Attach the lifting chain or rope to the lug/eyebolt/bail at the pump set on the
opposite side of the discharge nozzle.
This attachment point achieves a forward inclination of the pump set towards the
discharge nozzle, which allows the pump claw to hook onto the duckfoot bend.
Attaching the lifting
chain/rope - transportable
wet installation
Transportable wet installation
1. Attach the lifting chain or rope to the lug/eyebolt/bail at the pump set on the side
of the discharge nozzle.
Table 13: Types of attachment
Illustration
Type of attachment
920.26
914.26
Chain attached directly to the motor housing
914.26
Hexagon socket head cap screw
920.26
Nut
59-24.02
Looped lifting rope
59-24.02
Rope
59-24.02 / 885
59-17
914.26
920.26
Shackle with lifting rope or chain at the bail
59-17
Shackle
59-24.02
Rope
885
Chain
914.26
Hexagon socket head cap screw
920.26
Nut
885
Chain attached to the eyebolt with a shackle
59-17
Shackle
885
Chain
59-24.02
571
Lifting rope attached to the bail
59-24.02
Rope
571
Hoop
5 Installation at Site
Amarex KRT
27 of 78
Summary of Contents for Amarex KRT