WARNING
Hands or objects inside the pump casing
Risk of injuries, damage to the pump!
▷
Never insert your hands or any other objects into the pump.
▷
Check that the inside of the pump is free from any foreign objects.
▷
Take suitable precautions (e.g. wear safety goggles, etc).
WARNING
Improper positioning of pump set when checking the direction of rotation
Personal injury and damage to property!
▷
Use appropriate means to secure the pump set against overturning or tipping
over.
CAUTION
Pump set running dry
Increased vibrations!
Damage to mechanical seals and bearings!
▷
Never operate the pump set for more than 60 seconds outside the fluid to be
handled.
✓
The pump set is connected to the power supply. (
1. Start the pump set and stop it again immediately to determine the motor's
direction of rotation.
2. Check the direction of rotation.
Impeller rotation must be anti-clockwise (seen from the pump mouth end). On
some pump casings, the direction of rotation is marked by an arrow.
Fig. 5: Checking the direction of rotation
3. If the impeller is running in the wrong direction of rotation, check the electrical
connection of the pump and the control system, if necessary.
4. Disconnect the pump set from the power supply and make sure it cannot be
switched on accidentally.
5.3
Installing the pump set
Always observe the general arrangement drawing/outline drawing when installing
the pump set.
5.3.1 Stationary wet installation
5.3.1.1 Fastening the duckfoot bend
Depending on the pump size, the duckfoot bend is fastened with chemical anchors
and/or foundation rails.
5 Installation at Site
22 of 78
Amarex KRT
Summary of Contents for Amarex KRT
Page 77: ......