7.2.2.1.3 Lubricant quantity
Table 20: Lubricant quantity
Motor sizes
5 2, 6 2, 8 2, 12 2, 17 2,
22 2, 25 2,
4 4, 5 4, 7 4, 11 4, 16 4,
19 4, 21 4,
4 6, 6 6, 9 6, 12 6, 15 6,
19 6
23 2,
23 4, 29 4,
20 6, 26 6,
10 8, 17 8, 21 8
37 2, 55 2,
35 4, 50 4, 65 4,
32 6, 40 6, 50 6,
26 8, 35 8
Size
40-250
2.1 l
-
-
80-250
80-251
100-240
100-250/251
150-251
80-315/316
4.6 l
7 l
2.1 l
100-315
100-316
-
150-315
200-315/316
100-400/401
-
4.5 l
6.5 l
(D hydraulic system:
2.1 l)
150-400/401
151-401
200-330
200-400/401
250-400/401
300-400/401
7.2.2.1.4 Changing the lubricant
WARNING
Lubricants posing a health hazard
Hazardous to persons and the environment!
▷
When draining the lubricant take appropriate measures to protect persons and
the environment.
▷
Observe all legal regulations on the disposal of fluids posing a health hazard.
WARNING
Excess pressure in the lubricant reservoir
Liquid spurting out when the lubricant reservoir is opened at operating temperature!
▷
Open the screw plug of the lubricant reservoir very carefully.
1. Position the pump set as illustrated.
903
411.03
Fig. 20: Draining the lubricant
2. Place a suitable container under the screw plug.
3. Unscrew screw plug 903 or 903.03 with joint ring 411.03 and, if applicable, screw
plug 903.04 with joint ring 411.05. Drain the lubricant.
1. Position the pump set as illustrated.
Draining the lubricant
Filling in the lubricant
7 Servicing/Maintenance