Handbook OPTIFLEX 1300 C
OPTIFLEX
1300
C 8
0.6
Items supplied
•
signal converter connected to a cable, coaxial or rod signal guidance probe, as per order.
•
optional: sunshade (fastening material supplied)
•
quick-start guide
•
Ex instructions (for Ex version only)
•
calibration certificates with print-out of factory settings (where applicable)
•
a CD-ROM containing this handbook, special manuals for supplementary Ex data, data sheets,
certificates, device return form for repairs and servicing, PACTware software for remote configuration
and data display, links to KROHNE internet for further information such as telephone, fax and Email
numbers of all KROHNE companies and representatives worldwide.
Items not supplied
•
Nuts, bolts, gaskets and seals for fitting to existing nozzles, etc.
•
cabling and non-standard connections / cable glands
•
Service manual since - apart from exchanging entire subassemblies - this device can only be factory
serviced.
1.
Mechanical installation
1.1
Storage and handling
Handling
Mount OPTIFLEX 1300 C guided-radar (TDR) level meters on suitable process connections on a tank or
sump. The device weighs between 8 kg or 18 lb and 35 kg or 77 lb.
•
Lift the meter by the flange using two people to avoid damaging the probe.
•
Support the housing and avoid bending the probe while installing the device.
Handle probe with care!
Summary of Contents for optiplex 1300 c
Page 1: ......
Page 49: ...Handbook OPTIFLEX 1300 C 49 OPTIFLEX 1300 C 1 Volume measurement of liquids...
Page 50: ...Handbook OPTIFLEX 1300 C OPTIFLEX 1300 C 50 2 Volume measurement of solids...
Page 51: ...Handbook OPTIFLEX 1300 C 51 OPTIFLEX 1300 C 3 Mass measurement of liquids or solids...
Page 62: ...Handbook OPTIFLEX 1300 C OPTIFLEX 1300 C 62 Finding the advanced setup menu...
Page 95: ...Handbook OPTIFLEX 1300 C 95 OPTIFLEX 1300 C Note...