Handbook OPTIFLEX 1300 C
13 OPTIFLEX
1300
C
Probe straightness and avoiding entanglement
•
The cable must be straight once inserted into the tank.
•
The cable counterweight should not touch the bottom of the tank.
•
The cable must be far from other objects (e.g. mixers) to avoid entanglement.
Rigid length, Lr, of single and twin cable probes
Installation relative to other tank components
Objects near to the probe that influence measurement accuracy
Install the process connection far from protruding objects such as:
•
heating tubes
•
sudden changes in tank cross section
•
tank wall reinforcements and beams
•
weld lines
•
dip-stick pipes