1.
Substrate (Packaging foil)
2.
Platen (print area)
3.
Substrate adjustment roller
(Y-axis)
4.
Substrate guidance roller
5.
Package (before forming,
filling and sealing)
6.
A.
Move print to bottom of
package
B.
Move print to top of package
C.
Top of package
D.
Bottom of package
The print position can be moved with the substrate adjustment roller, Fig. 6.4 item 3, between the top and
bottom of the package. Be aware that the substrate contains an amount of prints/packages between the print
area and the seal area. So a substrate adjustment takes only effect after a certain amount of prints.
The package length must be smaller than twice the rack and pinion length (Ly) of substrate adjustment roller
package length. The print area can only then be positioned anywhere between the top and bottom of the
package.
Ly
< 2 Ly
A
B
n
n-1
n-2
6
5
B
A
1
1
3
2
C
D
4
Fig. 6.4
Substrate adjustment.
6.3.3 Air supply
1.
Place and connect the air regulator to the air supply and the coding unit.
2.
Adjust the pressure to 0,4 MPa (0,5 MPa for QiC 107i).
6.4 Mounting the control unit
1.
Find a secure location, which is easily accessible for operators, to mount the control unit. Refer to
Appendix B, Dimensions Control unit for the dimensions of the mounting holes.
2.
Locate the control unit on a position near the coding unit bracket and install the cables so that the
coding unit can rotate and move back and forth within the dimensions of the bracket.
3.
Check whether all of the cables are long enough to be connected to the connectors on the back of the
control unit. If not, correct it by relocating either the coding unit or the control unit and/or extend
the cable(s) if possible (the cable between the coding unit and control unit should not be extended).
4.
Connect the interface cable to the host machine. Use the electrical diagram, Appendix D X3 Circuit
diagram (input) and X3 Circuit diagram (output), to determine which interface option suits best
with the host machine.
CAUTION:
Make sure the interface cable is no longer than 30m. Using a cable longer than 30m can cause EMC
interference.
5.
Connect the interface cable to the interface port (X3).
6.
Connect the control/data cable, between the control unit and the coding unit (fixed length).
7.
Connect the control unit the local network if required (X2 - optional).
8.
Connect the mains supply (X1).
Summary of Contents for qic i series
Page 1: ...MANUAL QiC i series Thermal Transfer Printer Edition H325 IAE Rev 004 English kortho...
Page 14: ...INTRODUCTION kortho QiC i series H325 IAE Rev 004 1 6...
Page 30: ...PRINT PROCESS DESCRIPTION kortho QiC i series H325 IAE Rev 004 3 10...
Page 38: ......
Page 42: ...TRANSPORT STORAGE kortho QiC i series H325 IAE Rev 004 5 4...
Page 110: ...MAINTENANCE kortho QiC i series H325 IAE Rev 004 10 6...
Page 120: ...APPENDIX A SPECIFICATIONS kortho QiC i series H325 IAE Rev 004 A 4...
Page 133: ...APPENDIX C PART LISTS ILLUSTRATIONS H325 IAE Rev 004 kortho QiC i series C 7 Magazine QiC 30i...
Page 159: ...APPENDIX C PART LISTS ILLUSTRATIONS H325 IAE Rev 004 kortho QiC i series C 33...
Page 160: ...APPENDIX C PART LISTS ILLUSTRATIONS kortho QiC i series H325 IAE Rev 004 C 34...
Page 163: ...APPENDIX D CONNECTIONS H325 IAE Rev 004 kortho QiC i series D 3 X3 Schematic diagram input...
Page 164: ...APPENDIX D CONNECTIONS kortho QiC i series H325 IAE Rev 004 D 4 X3 Schematic diagram output...
Page 165: ...APPENDIX D CONNECTIONS H325 IAE Rev 004 kortho QiC i series D 5 X3 Circuit diagram input...
Page 166: ...APPENDIX D CONNECTIONS kortho QiC i series H325 IAE Rev 004 D 6 X3 Circuit diagram output...
Page 181: ...H325 IAE Rev 004 kortho QiC i series F 1 Appendix F Quick reference...
Page 182: ...APPENDIX F QUICK REFERENCE Kortho QiC i series H325 IAE Rev 004 F 2...
Page 186: ...bv korthofah P O box 3040 2220 CA Katwijk The Netherlands...