![Kortho qic i series User Manual Download Page 183](http://html1.mh-extra.com/html/kortho/qic-i-series/qic-i-series_user-manual_1999038183.webp)
H325 IAE
Rev.: 004
kortho
QiC i-series
G-1
Appendix G
Error list
The following errors / warnings can be generated by the system:
Error 00
Initialising Ethernet
Error 01
An error occurred while loading fonts.
Error 02
There are too many auto codes in the label.
Error 03
PIC not responding.
Error 04
A font in the label is not installed. Please install the font.
Error 05
The software has a problem with addressing the EEProm. Try again or upgrade the software.
Error 06
There is not enough memory space available for the font.
Error 07
The maximum storage space for a label is 96Kb. Reduce the file size.
Error 08
The printer received an incomplete message. Try again.
Error 09
The CRC check of the message is incorrect.
Error 10
Security token old. Login again.
Error 11
There is a problem with the Flash memory.
Error 12
There is a problem with the ribbon encoder.
Error 13
Unknown command received. Check the command or upgrade the firmware.
Error 14
Minimum value is
Error 15
Maximum value is
Error 16
Missing value.
Error 17
Maximum digits for
Error 18
Maximum characters for
Error 19
Date invalid.
Error 20
Time invalid.
Error 21
Wrong name or missing variable.
Error 23
Maximum users
Error 24
Access Denied.
Error 25
An unknown error occurred. Turn the printer off and back on after 10 seconds.
Error 26
A problem occurred while generating the label. Try again.
Error 27
Wrong coding unit connected. Connect the appropriate coding unit.
Error 28
Font Error.
Error 29
There is a problem with the font. Check Windows whether the font is correct.
Error 30
The printhead carriage does not return to home position.
Error 31
There is a problem with the ribbon transport.
Error 32
A timeout occurred for the print position.
Error 33
A print is missed. The print request signal was received while printing.
Error 34
The label is too small or the font is missing. The label must be at least 3 mm in size.
Error 35
A timeout occurred for the print-encoder.
Error 36
The ribbon encoder is connected incorrectly. Swap the wires.
Error 37
The carriage encoder is connected incorrectly. Swap the wires.
Error 38
First user must be manager.
Error 39
User list empty.
Error 40
Security disabled.
Error 41
Print magazine missing or placed incorrect.
Summary of Contents for qic i series
Page 1: ...MANUAL QiC i series Thermal Transfer Printer Edition H325 IAE Rev 004 English kortho...
Page 14: ...INTRODUCTION kortho QiC i series H325 IAE Rev 004 1 6...
Page 30: ...PRINT PROCESS DESCRIPTION kortho QiC i series H325 IAE Rev 004 3 10...
Page 38: ......
Page 42: ...TRANSPORT STORAGE kortho QiC i series H325 IAE Rev 004 5 4...
Page 110: ...MAINTENANCE kortho QiC i series H325 IAE Rev 004 10 6...
Page 120: ...APPENDIX A SPECIFICATIONS kortho QiC i series H325 IAE Rev 004 A 4...
Page 133: ...APPENDIX C PART LISTS ILLUSTRATIONS H325 IAE Rev 004 kortho QiC i series C 7 Magazine QiC 30i...
Page 159: ...APPENDIX C PART LISTS ILLUSTRATIONS H325 IAE Rev 004 kortho QiC i series C 33...
Page 160: ...APPENDIX C PART LISTS ILLUSTRATIONS kortho QiC i series H325 IAE Rev 004 C 34...
Page 163: ...APPENDIX D CONNECTIONS H325 IAE Rev 004 kortho QiC i series D 3 X3 Schematic diagram input...
Page 164: ...APPENDIX D CONNECTIONS kortho QiC i series H325 IAE Rev 004 D 4 X3 Schematic diagram output...
Page 165: ...APPENDIX D CONNECTIONS H325 IAE Rev 004 kortho QiC i series D 5 X3 Circuit diagram input...
Page 166: ...APPENDIX D CONNECTIONS kortho QiC i series H325 IAE Rev 004 D 6 X3 Circuit diagram output...
Page 181: ...H325 IAE Rev 004 kortho QiC i series F 1 Appendix F Quick reference...
Page 182: ...APPENDIX F QUICK REFERENCE Kortho QiC i series H325 IAE Rev 004 F 2...
Page 186: ...bv korthofah P O box 3040 2220 CA Katwijk The Netherlands...